Using The Inverter - Waeco Sine Power SP162 Instrucciones De Uso

Convertidor de ondas seno
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
SP160_SP350.book Seite 22 Donnerstag, 22. Februar 2007 1:51 13
All manuals and user guides at all-guides.com

Using the inverter

6.2
Connecting the SP352 and SP354
Caution
To set up the inverter, connect the red cable (fig. 1 4, page 3) to
the positive pole (+) of the battery and the black cable (fig. 1 5,
page 3) to the negative pole (-) of the battery. Make sure the bat-
tery poles are clean when connecting the terminals.
Caution
Only extend the connection line with cables with a cross section
that is equal to or greater than that of the connection line.
Caution
Do not reverse the polarity. Reversing the polarity of the connec-
tions will cause a great spark and the internal fuses will melt. These
fuses should only be replaced by a qualified electrician.
7
Using the inverter
➤ Connect your power consuming device, to the socket (fig. 1 1, page 3)
of the inverter.
Caution
Remember that in some cases it may be necessary to switch to
60 Hz.
Switching on at the device
➤ Switch the inverter on and off with the on/off switch (fig. 2 1, page 4) on
the device.
✓ When the switch is set to "ON", the LED (fig. 1 2, page 3) lights up
green.
Switching on with an external device
You can also switch the inverter on and off with an external switch.
➤ Set the on/off switch (fig. 2 1, page 4) on the device to "REMOTE".
22
SinePower

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sine power sp164Sine power sp352Sine power sp354

Tabla de contenido