with Clear Duty™ Technology
FASCIA LIGHTS - 4"
EMPS2QM(x)(x) - QUICK MOUNT
EMPS2SMS(x)(xxx)- SCREW MOUNT
EMPS2STS(x)(xxx) - STUD MOUNT THREADED
FASCIA LIGHTS - 3"
EMPS1QM(x)(x) - QUICK MOUNT
EMPS1SMS(x)(xxx)- SCREW MOUNT
EMPS1STS(x)(xxx) - STUD MOUNT THREADED
WARNING
•HIGH CURRENT interconnects must be properly terminated. Poor crimp quality can cause
heat build-up and fire. Follow crimp connector manufacturer instructions.
•DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to
vehicle Owner's Manual for deployment zones.
•Unit may become hot to touch during normal operation.
•Failure to properly install connectors, fuses or wiring may cause vehicle failure or fire.
•Installation must only be performed by trained technician. Installer must determine
vehicle wiring configuration and proper integration of system.
•Use proper wire gauge. All power wires connecting to positive (+) or negative (-) battery
terminal or local chassis ground (-) must be sized to supply at least 125% of max. current
and properly fused at power source.
•Install protective grommets when routing wire through firewall or metal.
www.soundoffsignal.com/sales-support. If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the
1.800.338.7337 / www.soundoffsignal.com
1
®
Red
Amber, Blue,
Green or White
Red
Amber, Blue,
Green or White
AFTER POWER IS ON, touching the WHITE wire to the ground will allow you to change
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
automated message). Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsignal.com.
S U P E R I O R C U S TO M E R R E L AT I O N S H I P S . S M A RT LY D E S I G N E D L I G H T I N G & E L E C T R O N I C S O L U T I O N S .
TECHNICAL SPECIFICATIONS
Dimensions (From Mounting Surface)
4" Screw Mount:
4.52"L x 0.92"H x 0.42"D
4" Stud,Threaded Mount:
4.04"L x 0.92"H x 0.42"D
4" Quick Mount:
4.04"L x 0.92"H x 0.42"D
3" Screw Mount:
3.425"L x .092"H x 0.42"D
3" Stud,Threaded Mount:
2.9"L x 0.92"H x 0.42"D
3" Quick Mount:
2.9"L x 0.92"H x 0.47"D
Input Voltage:
4" CURRENT CONSUMPTION (Amps)
12.8Vdc
Peak
Average
Peak
0.62
0.36
0.31
0.90
0.60
0.45
3" CURRENT CONSUMPTION (Amps)
12.8Vdc
Peak
Average
Peak
0.62
0.26
0.31
0.90
0.38
0.45
various settings on the module. (refer to page 8)
NOTICE:
WIRE HOOK-UP TABLE
WIRE COLOR:
RED
BLACK
GREEN**
9-32Vdc
WHITE to GROUND
WHITE to POWER
25.6Vdc
RED/WHITE
Average
** To sync multiple mPower lights, connect the Green
wire from each light together.
0.18
* Will NOT work w/ other sync products such as
Ghost, LED3, & 4 wire Intersector w/external flasher.
*Will Work with Sync 2 products nFORCE Secondary Lights,
0.30
nFORCE FIT and 5 wire Intersector Lights.
5
A FUSE
25.6Vdc
+Vdc
Average
Sync
0.13
Set-up/Function
+Vdc
+Vdc
0.19
5
A FUSE
FUNCTION:
Power (Primary)
Ground
Sync2 *
Setup Wire (See pg. 8*)
Function Wire
Power (Secondary)
RED/WHITE
GREEN
WHITE
RED
BLACK
mPOWER 9.16

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Soundoff Signal mpower EMPS2QM Serie

  • Página 1 Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices. Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
  • Página 2 INSTALLATION: ® Stud Mount, Threaded (Figure 1) 1. Pre-Drill per stud mount pattern indicated on page 11 (3") or per the supplied mounting template (4"). 2. Clean the surface as required. 3. Deburr hole as required. with Clear Duty™ Technology 4.
  • Página 3 INSTALLATION: ® Edge-Mount Bracket 1. Install Heat Sink onto “mPOWER Stud Mount, Threaded” light as ndicated. Wire passed through center hole. 2. Install bracket onto “mPOWER Stud Mount, Thread” light as indicated. Wire passed through rear relief and into lower with Clear Duty™...
  • Página 4 INSTALLATION: ® Multi-Mount Bracket 1. Pre-drill mount holes as required (bracket holes and spacing are indicated on page 10 (4") or page 11 (3"). 2. Place bracket onto desired vehicle’s surface and secure with screws (not provided). with Clear Duty™ Technology 3.
  • Página 5 INSTALLATION: ® Quick Mount w/Quick Clip 1. Feed wires through quick clip as shown. 2. Remove adhesive liner on the light and install clip to light. Make sure to properly align ends before placing down. 3. Route wires into recessed pocket lying flat in pocket. with Clear Duty™...
  • Página 6: Over-Voltage Protection

    ® with Clear Duty™ Technology OVER-VOLTAGE PROTECTION When an over-voltage condition is detected, the module will flash an over-voltage warning pattern of 50mS ON/950mS OFF to alert of the over-voltage condition and protect the electronics from damage due to heat/voltage. THERMAL COMPENSATION PROTECTION The LED module is designed to provide maximum power output while providing protection to the electronic components by reducing the output power at extreme temperatures.
  • Página 7 ® with Clear Duty™ Technology FUNCTION TABLES Changing the function table is only enabled when the LED module is in a flashing mode (disabled in cruise or steady ON functions). The functional operation of the LED module can be changed while applying the +V to the Red wire with the black wire connected to ground.
  • Página 8 ® with Clear Duty™ Technology COLOR SWAP This function is only valid for dual and tri-color light modules and can only be changed when the light module is in a flashing mode (disabled for single color modules and when light module is operating in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >2S and <3S (light will go steady high, steady low, off) then release.
  • Página 9 ® with Clear Duty™ Technology REMOTE MODE: FOR USE WITH bluePRINT SYSTEM ONLY Connecting the Green wire to ground before applying power to the Red or Red/White wires will place the LED module into remote mode and the light output color will be directly controlled by the input wires as shown below. For Cruise mode or Low Power control of the LED module, the signal to the control wires must be 100 +/- 2Hz using the duty cycle inputs listed below to produce the light output.
  • Página 10 ® with Clear Duty™ Technology FASCIA LIGHTS - 4” SCREW MOUNT HOLE TEMPLATE QUICK MOUNT HOLE TEMPLATE 54.5mm 54.5mm [2.145”] [2.145”] WIRE THRU-HOLE DRILL Ø8mm [Ø.315”] PRE-DRILL WIRE THRU-HOLE 2x Ø1mm DRILL Ø 8mm [Ø.04”] [Ø.315”] MULTI-MOUNT BRACKET 50mm [1.97”] 20mm [.787”] Ø...
  • Página 11 ® with Clear Duty™ Technology FASCIA LIGHTS - 3” 3” SCREW MOUNT HOLE TEMPLATE QUICK MOUNT HOLE TEMPLATE 39.50 ± 0.15mm 39.50 ± 0.15mm [1.555”±.006] [1.555”±.006] WIRE THRU-HOLE DRILL Ø8mm [Ø.315”] PRE-DRILL WIRE THRU-HOLE 2x Ø .1mm DRILL Ø 8mm [Ø.04”] [Ø.315”] 3”...
  • Página 12: Especificaciones Tecnicas

    El uso o la instalación incorrecta podrían anular la cobertura de la garantía. Para revisar nuestra Declaración de garantía limitada y Política de devolución para este o cualquier producto de SoundOff Signal, visite nuestro sitio web www.soundoffsignal.com/sales-support. Si tiene alguna consulta con respecto a este producto, comuníquese con Servicios técnicos de lunes a viernes de 8 a.
  • Página 13: Montaje

    INSTALACIÓN: ® Montaje con pasadores roscados (Figura 1) 1. Perforar utilizando el patrón de los pasadores de montaje en pagina 11(3”) o utilizando el patrón suministrado (4”). 2. Elimine las rebabas del orificio según sea necesario. 3. Limpie la superficie según sea necesario. with Clear Duty™...
  • Página 14: Soporte De Montaje En El Borde

    INSTALACIÓN: ® Soporte de montaje en el borde 1. Instale el disipador de calor en la luz “mPOWER Montaje con pasador roscado” según se indica. Pase el cable por el orificio central. 2. Instale el soporte en la luz “mPOWER Montaje con pasador with Clear Duty™...
  • Página 15: Soporte De Montaje Múltiple

    INSTALACIÓN: ® Soporte de montaje múltiple 1. Preperfore los orificios de montaje según sea necesario. Los orificios del soporte y el espaciado se indican en la página 10 (4") or página 11 (3"). 2. Coloque el soporte sobre la superficie deseada del vehículo y with Clear Duty™...
  • Página 16 INSTALACIÓN: ® Montaje rápido con pasador rápido 1. Pase los cables a través del pasador rápido como se muestra. 2. Retire el revestimiento adhesivo sobre la luz e instale la brida en la luz. Asegúrese de alinear los bordes de manera adecuada antes de colocar.
  • Página 17: Protección Contra Sobretensión

    ® with Clear Duty™ Technology PROTECCIÓN CONTRA SOBRETENSIÓN Cuando se detecte una condición de sobretensión, el módulo emitirá un patrón de advertencia de sobretensión de 50 mS ENCENDIDO/950 mS APAGADO para alertar acerca de la condición de sobretensión y proteger los componentes electrónicos del daño causado por el calor/la tensión.
  • Página 18 ® with Clear Duty™ Technology TABLAS DE FUNCIONES Las modificaciones de la tabla de funciones están habilitadas solo cuando el módulo LED se encuentra en modo parpadeo (inhabilitado en las funciones de modo crucero o estable ENCENDIDO). La operación funcional del módulo LED se puede modificar si se aplica el +V al cable rojo con el cable negro conectado a tierra.
  • Página 19: Interfaz Del Usuario

    ® with Clear Duty™ Technology CAMBIO DE COLORES Esta función es válida únicamente para módulos de luces dobles y triples y se puede modificar únicamente cuando el módulo de luces se encuentra en modo parpadeo (inhabilitado para módulos de color único y cuando el módulo de luces opera en funciones de modo crucero o estable ENCENDIDO).
  • Página 20 ® with Clear Duty™ Technology MODO REMOTO: PARA UTILIZAR CON EL SISTEMA bluePRINT ÚNICAMENTE La conexión del cable verde a tierra antes de aplicar potencia a los cables rojos o rojos/blancos colocará al módulo LED en modo remoto y el color de generación de luz será controlado directamente por los cables de entrada como se muestra a continuación. Para el control en Modo crucero o Potencia baja del módulo LED, la señal a los cables de control debe ser de 100 +/- 2 Hz con el uso de las entradas del ciclo de funcionamiento enumeradas a continuación para producir la generación de luz.
  • Página 21: Luces Superficiales - 10.16Cm

    ® with Clear Duty™ Technology LUCES SUPERFICIALES - 10.16cm PATRÓN DE ORIFICIO DE MONTAJE CON TORNILLOS PATRÓN DE ORIFICIO DE MONTAJE RÁPIDO 54,5 mm 54,5 mm [2,145”] [2,145”] ORIFICIO DE PASO DEL CABLE PERFORE Ø 8 mm [Ø 0,315”] PREPERFORADO ORIFICIO DE PASO DEL CABLE 2 x Ø...
  • Página 22: Luces Superficiales - 7.62Cm

    ® with Clear Duty™ Technology LUCES SUPERFICIALES - 7.62cm PATRÓN DE ORIFICIO DE MONTAJE CON TORNILLOS PATRÓN DE ORIFICIO DE MONTAJE RÁPIDO 39.50 ± 0.15mm 39.50 ± 0.15mm [1.555”±.006] [1.555”±.006] ORIFICIO DE PASO DEL CABLE PERFORE Ø 8 mm [Ø 0,315”] PREPERFORADO ORIFICIO DE PASO DEL 2x Ø...

Tabla de contenido