Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
• Be sure to DISCONNECT ALL POWER to the operator BEFORE installing the sensing edge.
• The gate or door MUST be in the fully opened or closed position BEFORE installing the LiftMaster
• Correctly install, connect, and test the sensing edge for proper operation.
®
• LiftMaster
Monitored Entrapment Protection devices are for use with LiftMaster
with ANY other product voids the warranty.
• Monitored external entrapment protection devices MUST be installed per the operator installation manual for each Entrapment Zone.
• NOT for use on swing gates.
INTRODUCTION
®
LiftMaster
sensing edges provide monitored
entrapment protection. Sensing edges are UL
Recognized Components and meet UL 325
requirements. A monitored entrapment protection
device MUST be installed in each entrapment zone.
For use with LiftMaster
®
door and gate operators
and wireless edge kit. Refer to the operator manual
to ensure compatibility.
NOT FOR USE ON SWING GATES.
Model WR4
4 Foot Wraparound Round Edge
Model WR5
5 Foot Wraparound Round Edge
Model WR6
6 Foot Wraparound Round Edge
Model WS4
4 Foot Wraparound Square Edge
Model WS5
5 Foot Wraparound Square Edge
Model WS6
6 Foot Wraparound Square Edge
OVERVIEW
Illustrations are for reference only, your application
may look different.
WIRING
1. Connect the wires to the EDGE terminal on the operator control board, the EYE/EDGE terminal on the expansion board, or to the LiftMaster LMWEKITU wireless edge transmitter. A
wireless edge transmitter is recommended (not provided). Place an obstruction at different points of gate travel. 2. Reconnect power and operate gate. The gate will stop and reverse.
3. Test ALL installed edge sensors for proper operation.
Control Board
INSTALLATION
1. Measure 1-1/2" (3.8 cm) from the top edge of the gate and 0.8" (2 cm) off center of the gate as shown. Drill a
1/2" (1.3 cm) hole in this location.
2. Insert the wire from the wraparound edge through the hole and fit the edge around the gate frame.
3. Measure 2" (5.1 cm) from the top of the edge and pre-drill a 1/8" (0.3 cm) hole through the mounting flange
and gate. Continue to pre-drill holes every 12" (30.5 cm) for the length of the gate.
4. Secure the edge to the gate with self-tapping screws (not provided).
For close cycle
Expansion Board
For open cycle
WRAPAROUND EDGE
Models WR4, WR5, WR6, WS4, WS5, WS6
®
Monitored Entrapment Protection device.
®
UL 325 compliant Gate and Commercial Door Operators and accessories ONLY. Use
0.8" (2 cm)
1/2"
(1.3 cm)
For open or
close cycle
Wireless edge transmitter

Publicidad

loading

Resumen de contenidos para LiftMaster WR4

  • Página 1 WIRING 1. Connect the wires to the EDGE terminal on the operator control board, the EYE/EDGE terminal on the expansion board, or to the LiftMaster LMWEKITU wireless edge transmitter. A wireless edge transmitter is recommended (not provided). Place an obstruction at different points of gate travel. 2. Reconnect power and operate gate. The gate will stop and reverse.
  • Página 2 1. Connecter les fils à la borne EDGE (bordure) sur le tableau de commande de l’actionneur, à la borne EYE/EDGE (cellule photoélectrique/bordure) du tableau d’extension ou à l’émetteur sans fil de la bordure LiftMaster LMWEKITU. Un émetteur sans fil de bordure est recommandé (non fourni). Placer un obstacle à différents points de la trajectoire de la barrière. 2. Reconnecter l’alimentation et faire fonctionner la barrière.
  • Página 3 CONEXIONES 1. Conecte los cables a la terminal del BORDE en el tablero de control del operador, la terminal del BORDE en el tablero de expansión, o en el transmisor de borde inalámbrico LiftMaster LMWEKITU. Se recomienda un transmisor de borde inalámbrico (no incluido). Coloque una obstrucción en diferentes puntos de la trayectoria de la compuerta. 2. Reconecte la corriente y opere la compuerta. El operador debería detenerse y arrancar en dirección opuesta.
  • Página 4 © 2016, LiftMaster All Rights Reserved Tous droits réservés 01-38305 Todos los derechos reservados...

Este manual también es adecuado para:

Wr5Wr6Ws4Ws5Ws6