- When the saw is not going to be used for a long period.
- Before to start operation after a long period it has not been
used.
All removable parts must be removed and washed. Wash
them with running water and neutral soap.
Use Your QR Code Reader to access more
information regarding the cares needed
when handling stainless Steel.
Use a clean cloth or a soft brush to remove residues.
Wash, sanitize, rinse and dry all the components.

6. MAINTENANCE

Maintenance must be considered a set of procedures
with the purpose to keep the equipment best operating
conditions, therefore increasing the equipment life and
safety.
Cleaning – check item 5 CLEANING
Wiring - Check all wires regarding deteriorate conditions as
well as all electric contacts (terminals) regarding tightening
and corrosion .
Contacts – ON/OFF switch, emergency button, reset button,
electronic circuits, etc., check the equipment in order to

7. PROBLEM SOLUTIONS

PROBLEMS
- The equipment does not
switch on.
- Machine switch on but stop
during operation
- Smoke or burn smell.
- Unusual noises.
CAUSES
- Lack of Power;
- Problem with the internal or
external electric circuits.
- Belts not fastened enough.
- ON/OFF Switch with bad contact.
- Problem with the internal or
external electric circuits.
- Defective bearing.
assure that all components are correctly working and the
equipment operation is normal .
Installation – make sure the installation followed item 3
instructions.
1 – Each month check:
- Check the electrical installation
- Measure the voltage at the socket
- Measure the working current and match it with the
nominal current
- Check the tightening of all electric terminals to avoid bad
contacts
- Check electric motor shaft clearance
- Check the wiring for overeating, insulation failures and
mechanical damages.
2 Each three month checks
- Check electrical components such as ON/OFF switch,
emergency button , reset button, electronic electric circuits ,
overeating, insulation failings, or mechanical damages
- Check bearings clearances
- Check retainers, O'rings, V'rings and other seals.
Use Your QR Code Reader to access
more information regarding safety and
maintenance.
- Check if there is electric power.
- Call Technical Assistance.
- Call Technical Assistance;
- Call Technical Assistance.
- Call Technical Assistance.
- Call Technical Assistance.