Agitator Overload Protector; Performance Indicator - Kenmore 116.33922 Manual Del Propietário

Ocultar thumbs Ver también para 116.33922:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MOTOR PROTECTION
SYSTEM
Motor Protector
This vacuum has a motor protector
by-pass
valve which automatically
opens to provide
cooling air to the suction motor when a clog
prevents the normal flow of air to the motor.
If the by-pass valve opens to prevent motor
overheating
and possible damage
to the
vacuum, you will notice a change of sound
as air rushes through the valve opening.
To correct problem:
See the TROUBLE-
SHOOTING
chart.
NOTE: The motor
protector may open
when using
attachments
or when
cleaning new carpet,
due to reduced airflow
by the attachments
themselves
or by new
carpet fuzz filling the
bag quickly.
See the
TROUBLESHOOTING
section.
Motor
Protector
Note: Do not block motor protector.
Thermal
Protector
This vacuum has a thermal protector
which
automatically
tdps to protect the vacuum
from overheating.
If a clog prevents the
normal flow of air to the motor, the thermal
protector turns the motor off automatically
to
allow the motor to cool in order to prevent
possible damage to the vacuum.
During this
time the headlight
remains on.
To correct problem:
If this occurs, turn the
vacuum off and unplug the power cord from
the outlet to allow the vacuum to cool and
the thermal protector to reseL Check for
and remove clogs, if necessary.
Also
check and replace any clogged filters.
Wait approximately
thirty (30) minutes
and plug the vacuum in and turn back on
to see if the motor protector
has reset.
The motor protector
will not reset if the
vacuum is not turned off even if the
vacuum has cooled down.
AGITATOR
OVERLOAD
PROTECTOR
The agitator has
built-in protection
against motor
damage should the
agitator jam. If the
agitator slows down
or stops, the agitator
overload protector
shuts off the agitator.
The suction motor
will continue to run.
Agitator Over/oad
Reset Button
To correct problem:
Tum off and unplug
vacuum, remove obstruction,
then press
reset button.
To reset:
Push in the agitator overload
protector
button.
PERFORMANCE INDICATOR
SOME
MODELS
When the unit is running with normal air
flow, the light on the performance
indicator
is off. The light comes on whenever
the
airflow becomes
blocked.
If that occurs,
check the disposable
dust bag, motor safety
filter and other possible clog locations
shown in CLOG REMOVAL.
To correct
problem:
See the
TROUBLE-
SHOOTING
chart.
NOTE: The
light may also
come on
when using
attachments,
due to
reduced
airflow
through
the
attachment.