87 620
p p p
PARAMETERS
Reset
interlocking by
keys (6 + 4)
Interlocking of
access to preset
P1
Interlocking of
access to preset
P2
Interlocking of
access to gain G
Interlocking
mode for reset,
presets and gain
58/231
VALUES
*
-
/ ) 
-
 * "
*

/ ) 

 * "
*

/ ) 

 * "
*
  / ) 
   * "
*
 ( ( / ) 
 ( (  * "
DESCRIPTION
- Manual reset possible (keys 6 + 4)
- Reset by keys, interlocked or delayed (see
Interlocking mode parameter)
- Access to preset P1 possible (keys P + 1)
- Access to P1 interlocked (or possible after
10 s, see Interlocking mode parameter)
- Access to preset P2 possible (keys P + 2)
- Access to P2 interlocked (or possible after
10 s, see Interlocking mode parameter)
- Access to gain possible (keys P + 3)
- Access to gain interlocked (or possible after
10 s, see Interlocking mode parameter)
- Access to interlocked parameters possible
after pressing > 10 s
- Access to interlocked parameters impossible
12 - 2005