87 620
p p p
8 - Batch counter
8.1 - Description of the batch counter mode
" . !
The CPT4 multifunction electronic counter configured in batch counter mode
enables:
- counting/downcounting of electrical pulses,
- display of current value, taking into account the Gain G,
- manual, electrical or automatic setting to zero/reset of current value,
- activation of a contact OUT2 when the main preset value P2 is reached,
- increment of a batch counter each time preset value P2 is reached,
- display of current value of the number of batches (keys P and 4)
- manual, electrical or automatic reset,
- activation of a contact OUT1 when the number of batches reaches the
preset value P1,
- manual setting to zero of batch counter.
- The output OUT2 is activated, or not, on an intermediate reset, according
to the counter user settings. For units with a single preset, the
corresponding output is OUT1.
74/231