Genie AWP Super Serie Manual De Mantenimiento página 119

Ocultar thumbs Ver también para AWP Super Serie:
Tabla de contenido

Publicidad

N
M
L
K
P2
EMERGENCY
STOP
WH
RD
N.C.
EN1
PLATFORM
CONTROL
SW8
CONTROL
BOX
ACTIVATE
SWITCH
BK
SW11
UP
PLATFORM
BK
UP/DOWN
DOWN
SWITCH
*N17
NARROW PLATFORM UNITS
WH AND BK WIRES REPLACE
BL AND OR WIRES.
WH
EN4
GND
POWER TO
PLATFORM
GROUND
GFCI
STUD
GN/YL
RECEPTACLE
110V AC / 220V AC
BK
J
I
H
P1
RD
EMERGENCY
STOP
BK
RD
RD
BK
BK
BK
N.C.
RD
W3
1
2
3
KS1
12V DC POWER INPUT
NEGATIVE 12V DC INPUT
PLATFORM
POSITIVE 12V DC INPUT
RD
+
RD
LEVELING
INDICATORS
L5
BK
BK
POWER INDICATOR
N.O.
KS1
L14 L12
L6
-
GROUND
INDICATOR FOR
BK
BK
AUXILIARY LOWERING
BK
L15
L13
BL
B4
RD
N.O.
8 AA
BATTERIES
1 SECOND TIME DELAY 12V DC OUTPUT
L7
SW12
DC MODEL:
LOW BATTERY
AUXILIARY
U10
INDICATOR
DOWN
N.O.
PC BOARD
BL
BL
GND
WH
GROUND
STUD
GND
GROUND
STUD
QD7
POWER
STRAIN RELIEF
INPUT
PLUG
TO MOTOR
D5
POWER
QD3
1
2
3
4
6
7
SUPPLY
AC
QUICK DISCONNECT A
BK
TO PLATFORM
1
2
3
4
6
7
B2
B2
RD
BATTERY
BATTERY
12V DC
12V DC
OR
BK
+
+
POWER
GN/YL
BL
INPUT
PLUG
WH
WH
D5
-
-
POWER SUPPLY
AC
BK
GN/YL
BK
Primera edición • Segunda impresión
G
F
E
1
2
3
WH
LED 1 12V DC INPUT
4
OR
LED 2 12V DC INPUT
5
BL
LED 3 12V DC INPUT
6
RD
LED 4 12V DC INPUT
7
BK
12V DC OUTPUT
8
RD
12V DC OUTPUT
9
12V DC OUTPUT
9A
WH
GROUND
10
RD
12V DC MOTOR SOLENOID OUTPUT
11
12
OR
12V DC UP SIGNAL INPUT
13
W4
QD4
BK
7
7
RD
6
6
BL
5
5
WH
4
4
EN2
OR
3
3
GROUND
BL
2
2
WH
CONTROL
1
1
BOX
POWER UNIT
RD
OR
WH
OR
WH
WH
F1
M5
15 AMP
MOTOR
CHARGE
BK
BATTERY
BK
WH
Y30
N.O.
DUMP VALVE
N° de pieza 38139SP
Sección 7 • Esquemas
Esquema eléctrico
Modelos TUV de CC IWP Super Series
con extensión horizontal
D
C
B
STEER HANDLE
DRIVE
MANIFOLD
CONTROLS
P3
SW21
EMERGENCY
DIRECTION - REVERSING
STOP
Y5
SAFETY SWITCH
(OPTION)
DRIVE
BK
FORWARD
WH
BK
WH
Y32
DRIVE
WH
FUNCTION
SW22
BK
OR
FORWARD/
REVERSE
Y6
SWITCH
RD
DRIVE
BK
REVERSE
OR
BK
RD
S7
TILT
SENSOR
W6
TERMINAL
GND
STRIP
GROUND
RD
RD
STUD
BK
RD
BK
WH
RD
BK
YL
GN
OR
SW18
BL
BK
WH
SW17
BK
BK
PLATFORM
TO
OUTREACH
PLATFORM
OPTION
LS1
PLATFORM
EXTENTION
WH
BK
TO BASE
QUICK DISCONNECT A
QD3
TO PLATFORM
Genie AWP Super Series e Genie IWP Super Series
A
1
2
3
RD
BK
OR
WH
BK
GN
4
5
N.O.
Y7
PLATFORM
DOWN
WH
6
RD
WH
7
8
7 - 21

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido