3

Installation instructions

3.1 AS-Interface Addresses
Before connecting to the AS-Interface bus: assign an un-
used address to each slave.
Please note
– The valve terminal type CPV..-GE-ASI-8E8A-Z contains
2 AS-Interface slaves coupled together. The valve
terminal behaves on the AS-Interface bus like two
individual valve terminals each with 4 inputs and 4
outputs (valve locations).
– The addresses are saved electronically and can be
modified at least 10 times. After that the valve ter-
minal maintains the addresses last set.
– Automatic addressing with the function "Automatic
address assignment" of the master is not possible.
Example of address assignment (Siemens S7)
IO code 7
:
Slave 2:
H
D3
I/O
In the example the slaves have the following AS-Interface
addresses:
– slave 1: address # 5
– slave 2: address # 4
Input
PLC
‹7 6 5 4 3 2 1 0› ‹7 6 5 4 3 2 1 0›
res.
#1
...
#2
#3
...
#4
#5
36
#6
#7
...
...
...
Festo CPV..-GE-ASI-8E8A-Z 0106a English
Slave 1:
D2
D1
D0
D3
D2
D1
I/O
I/O
I/O
I/O
I/O
I/O
Output
= Assigned addresses
with IO code 7
res.
#1
#2
#3
#4
#5
#6
#7
D0
I/O
H
19