3.6 Connection example – valve terminal type 10
AS-Interface master
1
2
Festo combi power
unit
Load voltage can
3
be switched off
3.7 Converting the valve terminal
The CPV valve terminal can be fitted with double-solenoid
and/or single-solenoid valves. During conversion, the new
valve terminal configuration must be set on the DIP
switches on the bottom of the electric sub-base.
1
DIP switch 1:
Valve locations
1 to 4 (slave 1)
2
DIP switch 2:
Valve locations
5 to 8 (slave 2)
Instructions on removign the electric sub-base can be
found in the Pneumatics Manual. The permitted valve com-
binations as well as the relevant DIP switch settings can be
found in the table in section 3.3.
28
1
2
0
1
2
3
1
Festo CPV..-GE-ASI-8E8A-Z 0106a English
3
4
5
6
7
2