SPECIFICATIONS – EC6, EC7, EH7, HT7, SC7, SCC7 SERIES
Model
Motor
Number
HP
EC650120M
1/2
EC650120T
1/2
EC750120M
1/2
EC750120T
1/2
EC7100220M
1
EC7100220T
1
EC7100520M
1
EH750120M
1/2
EH750120T
1/2
EH7100220M
1
EH7100220T
1
SCC750120T
1/2
SC750120M
1/2
SC750120T
1/2
SC750220M
1/2
SCC775120T
3/4
SC775120M
3/4
SC775120T
3/4
SCC775220T
3/4
SC775520M
3/4
HT750120T
1/2
SPECIFICATIONS – SC9, SCC9, EC9 SERIES
Model
Number
SC975220T, SCC975220T****
SC975220M, SCC975220M
SC975320M, SCC975320M
SC975420M, SCC975420M
SC9100220M, SCC9100220M
SC9100220T, SCC9100220T****
SC9100320M, SCC9100320M
SC9100420M, SCC9100420M
SCC9100520M
SC9150220M, SCC9150220M
SC9150320M, SCC9150320M
SC9150420M, SCC9150420M
SCC9150520M
SC9200220M, SCC9200220M
SC9200320M, SCC9200320M
SC9200420M, SCC9200420M
SCC9200520M
EC9200220M
EC9200320M
EC9200420M
**** Model numbers ending in "T" include Float Switch model number PW217-224. Float Switch PW217-224 turns on at 22" and turns off at 13".
PERFORMANCE – EC6, EC7, EH7, HT7, SC7, SCC7 SERIES
GPM AT TOTAL FEET
Model
10
20
30
CAPACITY GALLONS/MINUTE
EC650120M
90
75
60
EC650120T
90
75
60
EC750120M
110
95
80
EC750120T
110
95
80
EC7100220M
100
95
90
EC7100220T
100
95
90
EC7100520M
100
95
90
EH750120M
60
60
60
EH750120T
60
60
60
EH7100220M
62
62
62
EH7100220T
62
62
62
Load
Volts
Phase
Amps
115
1
115
1
115
1
115
1
230
1
230
1
575
3
115
1
115
1
230
1
230
1
115
1
115
1
115
1
230
1
115
1
115
1
115
1
230
1
575
3
115
1
Motor
HP
Volts
3/4
230
3/4
230
3/4
208-230
3/4
460
1
230
1
230
1
208-230
1
460
1
575
1-1/2
230
1-1/2
208-230
1-1/2
460
1-1/2
575
2
230
2
208-230
2
460
2
575
2
230
2
208-230
2
460
No flow
at height
40
50
60
70
80
shown
below
35
50
35
50
60
35
59
60
35
59
80
65
40
9
72
80
65
40
9
72
80
65
40
9
72
55
50
30
5
71
55
50
30
5
71
62
60
50
40
20
89
62
60
50
40
20
89
Max.
Individual
Branch Circuit
Required (Amps)
12.0
15
12.0
15
13.0
15
13.0
15
6.6
10
6.6
10
2.7
6
12.0
15
12.0
15
8.7
10
8.7
10
11.2
15
11.2
15
11.2
15
5.5
10
12.0
15
12.0
15
12.0
15
6.7
10
1.8
6
12.0
15
Phase
1
1
3
3
1
1
3
3
3
1
3
3
3
1
3
3
3
1
3
3
Model
SCC750120T
SC750120M
SC750120T
SC750220M
SCC775120T
SC775120M
SC775120T
SCC775220T
SC775520M
HT750120T*
* Flows are for 200° F water temperature.
2
Discharge
Switch Setting
Adapter
in inches (mm)
Size (inches)
On
2
2
18.1(460)
2
2
18.1(460)
2
2
18.1(460)
2
2
2
18.1(460)
2
2
18.1(460)
3
20(508)
2
2
20(508)
2
3
20(508)
2
2
20(508)
3
20(508)
2
2
17.8 (452)
Full
Individual Branch
Load
Circuit Required
Amps
(Amps)
7.5
10
7.5
10
8.0
10
4.0
10
8.5
15
8.5
15
8.5
15
4.1
10
3.5
6
12.0
15
9.0
15
4.7
10
3.8
6
13.0
15
10.0
15
5.3
10
4.2
10
11.0
15
7.5
10
3.8
6
GPM AT TOTAL FEET
10
20
30
CAPACITY GALLONS/MINUTE
100
40
100
40
100
40
100
40
115
60
115
60
115
60
115
60
115
60
65
60
50
Off
9.1(231)
9.1(231)
9.1(231)
9.1(231)
9.1(231)
11(279)
11(279)
11(279)
11(279)
11(279)
8.8 (224)
Dischagee
Adapter
Size (inches)