ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y172, RM-Y173) to perform the circuit adjustments in this section.
Test Equipment Required: 1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
4-1. SETTING THE SERVICE ADJUSTMENT
MODE
1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a
second of each other:
Display
Channel 5
SERVICE ADJUSTMENT MODE ON
1. The CRT displays the item being adjusted.
Mode
Category
service
defl
Signal
ntsc
Type
vchp
00000000
2. Press 1 or 4 on the Remote Commander to select the item.
3. Press 3 or 6 on the Remote Commander to change the data.
4. Press MUTING then ENTER to write into memory.
SERVICE ADJUSTMENT MODE MEMORY
Display
Mode
Category
service
defl
hsiz
Signal
ntsc
Type
vchp
00000000
1. Press 8 then ENTER on the Remote Commander to initialize.
Display
Mode
Category
Item
service
defl
hsiz
16
Signal
write
ntsc
Type
vchp
00000000
00000000
2. Turn set off then on to exit service adjustment mode.
SECTION 4: CIRCUIT ADJUSTMENTS
Sound Volumne +
Power
Display
Item
Item
Data
hsiz
16
00000000
Item
Item
Data
MUTING
Green
16
write
00000000
ENTER
Item
Data
MUTING
Green
ENTER
Red
Carry out Step 1 when adjusting
IDs 0-6 and when replacing and
adjusting IC1003
4-2. MEMORY WRITE CONFIRMATION
METHOD
1. After adjustment, pull out the plug from the AC outlet, then replace
the plug in the AC outlet again.
2. Turn the power switch ON and set to Service Mode.
3. Call the adjusted items again to confi rm they were adjusted.
4-3. REMOTE ADJUSTMENT BUTTONS AND
INDICATORS
MUTING
(Enter into
memory
DISPLAY
(Service Mode)
1
Disp. (Item up)
2
(Device Item Up)
4
Disp. (Item down)
8
(Initialize)
Red
VOLUME (+)
(Service Mode)
— 16 —
KV-21FE13 / 21FE13C / 21FM13 / 21FM13C
POWER
(Service Mode)
3
Item (Data up)
6
Item (Data down)
5
(Device item down)
ENTER
(Enter into
memory
0
(Remove from
memory)
RM-Y173