- Remove the blanking module (E) fig. 17, from the back of the plate using
a screwdriver, working in sequence from bottom to top (first remove the
end section, then key 1 and finally the blanking module.
- Fit the external key (F) (supplied) to the plate by pushing it lightly into
place.
- Insert the light diffuser (h) to ensure even lighting of the name cards.
ESECUZIONE DA ESTERNO PARETE
- Close the entrance panel, securing it to the frame with the aid of a screw-
driver.
Fig.18
A
B
C
P
EN
POWER SUPPLY UNIT (TYPE 6922.1)
Technical specifications
- Supply voltage: 110 - 240 Vac
- Maximum current draw at 110 V 1 A
- Maximum current draw at 240 V 0.6 A
- Power dissipation 15 W
- BUS output voltage (1/2, B1/B2) 28 Vdc nominal (SELV - EN60950-1).
- Maximum current output: 1.6 A (1A continuous + 0,6A INT. with cycle 30s
ON - 180s OFF).
- Operating temperature -5 °C +35 °C (indoor)
- 8 x 17.5 mm module, dimensions 140 x 115 x 65mm
- for installation in consumer units with DIN rail (60715 Th35), or
wall-mounting with masonry plugs and screws provided.
Installation rules
Installation must be carried out in accordance with current regulations
governing the installation of electrical equipment in the country where the
products are located. Ensure minimum clearance distances all round the
device in order to provide sufficient ventilation. When mounted internally
of an enclosed switchboard, use a 12 x 17.5 mm module switchboard. The
device must not be exposed to water drip, splash or spray.
Caution: To avoid injury, the device must be secured to the wall following
the directions given in this document. The power supply must be connected
to the a.c. mains by way of an easily accessible double pole switch having
G
a gap of at least 3 mm between contacts.
Regulatory compliance
LV Directive
EMC Directive
Standards EN60065, EN61000-6-1, EN61000-6-3
h

WIRING DIAGRAM

Videokit type 68IA/R (black/white), type 68IA/RC (colour)
- It is possible to reverse the polarity of the two connecting wires between
power supply unit and monitor and between power supply unit and en-
trance panel.
L
- The cable recommended for connecting the kit is type 732h (2x1mm²)
and/or 732I ( 2x1mm²). If the cable used is not one of those indicated
above, the following guarantees do NOT apply.
I
- The installation is guaranteed up to a maximum distance of 150 metres.
M
Distance intended as the straight-line distance between the 2 devices
furthest apart (e.g. the furthest entrance panel and the furthest monitor).
The total length of extended cable must not exceed 500 metres. These
N
maximum distances apply to both B/W and colour installations.
- Electric locks connected to the entrance panels must have a maximum
input current of 1 A at a voltage of 12 Vdc.
- Electrical disturbances or discharges may affect the operation of the de-
vices. Therefore we recommend laying the cables inside separate tubes.
O
A1 + A2 + B1 + B2 = Max 150 m
A1 + A2 + C1 + C2 = Max 150 m
B2
C1
B1
A1
A2
C2