5.2.2.- Fixed station installation:
For use as a fixed station, an external 13.8 VDC power supply is required. We recommend a power
supply that provides a current of at least 12 A.
Note:
- Do not connect the external power supply to the 230 VAC socket until all the transceiver
connections are complete.
1. Make sure the transceiver and the power supply are OFF mode.
2. Connect the transceiver DC power cable to the external power supply connectors (Red wire:
positive, black wire: negative).
● Use the supplied DC power cable to connect the transceiver to the external power supply. Never
connect the transceiver to a 230 VAC wall outlet.
● Don´t use a power cable with a smaller section than the one supplied.
3. Connect the DC power cable to the transceiver.
● Press firmly on the DC power cable connector until you hear a "click" sound.
5.2.3.- Replacing the fuse:
If the fuse blows, check the cause and solve the problem. Once the problem is solved, replace the
fuse by other of the same characteristics as the one supplied with the transceiver. If the new fuse
blows again, disconnect the DC power supply and contact with the Authorized Technical Service.
Transceiver (in DC connector)
Note:
- Use only the specified type and the rated value of the fuse; otherwise the transceiver could
be damaged.
Fuse position
DC power cable
Fuse rated current
10 A
10 A