IMPORTANT REMARKS

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS CAREFULLY BEFORE
PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED
WITH THE SYMBOL
RECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS
OFELECTRICALEQUIPMENT"andmustrespectthelocalstandards
and regulations in force. All materials used must be approved and
must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or maintenance
operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which
it has been made. "i.e. for the automation of one or two hinged
gates".
The appliance may be used to operate hinged gates and doors, with gate
leaves up to 3m in length and the following characteristics:
- maximum weight for 2-3m long gates = 550 Kg
- maximum weight for gates less than 2m long = 700 Kg
• The unit may be fitted both to the right and to the left of the pas-
sageway.
• This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and
therefore dangerous.
The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing
circuit is not efficient.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not
on the public side of the gate. The gates must not swing outwards
onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate
at all times.
5) At least two warning signs (similar to the example on the right) should
be placed, where they can be easily seen by the public, in the area of
the system of automatic operation. One inside the property and one
on the public side of the installation.
These signs must be indelible and not hidden by any objects (such
as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of a
fixed structure the space must be protected by
an anticrush buffer (fig. 1, detail 11).
8) A correct earth connection is fundamental in
order to guarantee the electrical safety of the
machine
9) If you have any questions about the safety of the
gate operating system, do not install the operator.
Contact your dealer for assistance.
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE COR-
WARNING
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
TECHNICAL DESCRIPTION
800/HL251CL
Reversible geared motor, maximum opening 110°.
806/HLCF1
Embedding case in zinc plated steel with transmission
lever for 110°.
800/HL2518CL Reversible geared motor, gate opening 118°-360°.
806/HLCF18
Embedding case in zinc-plated steel with accessories for
gate opening 110°-360°.
• Single piece geared reduction unit;
- Single phase drive motor with an incorporated overload protector and a
permanently lubricated reversible reduction unit mounted on a cast iron
stator.
- Rubber sealing gasket;
- Key operated manual release mechanism.
• Embedding case in hot rolled zinc-plated steel;
- Release unit housing in pressed aluminium.
• Transmission levers in zinc-plated steel;
- Gate fastening bracket in zinc-plated steel.
USER INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children.
Before starting with the installation of the system check that the structure
which is to be automated is in good working order and respects the local
standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that the hinges turn easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
The appliance is not suitable for continuous operation and must be contained
within the value stipullated (see technical data on page 20).
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the
entire opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening angle
of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots and hinges, and their good
working order (the upper and lower hinges/pivots must be aligned on the
same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig.1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle of
the gate to which it is to be applied (see duty cycle on page 20).
FITTING THE UNIT
- Choose the ideal position for the foundation case according to the opening
angle (90°-110°-180° fig.5) and the position of the gate pivot.
- Place a mechanical travel buffer in the closing direction.
- Dig the foundation hole "A" (fig.6) sufficiently large to house the foundation
case and run a drain channel up to the hole "B".
- Run the channelling for the cables up to the hole "C".
- Insert the six round headed screws "E" into the holes on the bottom of
the case and fasten down using the supplied nuts and washers.
- Place the foundation case in the hole with the pin perpendicular to the
upper gate pivot "D", cover the case in concrete and check that it is in
square and that the upper edge protrudes by at lkeast 3 mm from the
ground.