Features
• Easy installation with strip terminal
• Output adjustable from 12V to 15V
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
o
C
• OVP Option for 12V and 15V.
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
SLD-12-1010-12T
+12V/1.0A or +15V/0.8A
*Outputs are tied common
Operating Temperature Range
0 to +50
o
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (For 24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
EMI/RFI
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
Input Specifications
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Multi Input (all units)
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
50 µsec at 50% load change
Transient Response Time
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Output Specifications
0.05% for +/- 10% change
Line Regulation
0.05% for 50% change
Load Regulation
3.0 nV maximum peak-to-peak
Ripple
DC Output Adjustment Range
+/- 5% minimum
Overvoltage Protection
OVP is optionally available
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Model: SLD-12-1010-12T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
Output 1
Output 2
-12V/1.0A or -15V/0.8A
C (Derate to 40% at +70
o
C)
C
o
Output Adjustment
Step 1:
Check the input AC connections
Step 2:
Connect the AC input according to the table below.
Step 3:
Use VR6 V.ADJ to adjust +V. Adj. to +15V or +12V
Step 4:
Use VR4 V.ADJ to adjust -V. Adj. to -15V or -12V
Input AC Connections
For use
at:
Connect
100 VAC
1-3, 2-4
120 VAC*
1-3, 2-4
220 VAC
2-3
230 VAC
2-3
240 VAC
2-3
*Note: Unit is shipped for 120V input from factory.
Mechanical Dimensions: inches (mm)
4.00 " ( 102)
. 25" (6.5 )
3.375" (86)
VR4
V.ADJ
VR6
V.ADJ
OVP
(OPTIONAL )
.50" (12.5)
. 75" ( 19)
Note: I. LIM is factory set and should not be adjusted by users.
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
nut assembly.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Apply AC to:
Primary Fuse
1 & 5
0.63A/125V
1 & 4
0.63A/125V
1 & 5
0.315A/250V
1 & 4
0.315A/250V
1 & 4
0.315A/250V
.75" ( 19)
. 45" (11.5)
VR3
I.LIM
VR5
I.LIM
PEM NUT HOLES
.188 "
6-32 MTG (2 PLACES)
(4.8 )
°
MTG HOLES
(6 PLACES)
MAX WEIGHT:
2.21 LBS
(1 KG )
Case H1
Case H1
-12
COM
+12
4
2
3
1
5

Publicidad

loading

Resumen de contenidos para Emerson SLD-12-1010-12T

  • Página 1 Linear Open Frame DC Power Supplies Output Adjustment Silver Line Instruction Manual Step 1: Check the input AC connections Model: SLD-12-1010-12T Step 2: Connect the AC input according to the table below. Step 3: Use VR6 V.ADJ to adjust +V. Adj. to +15V or +12V Step 4: Use VR4 V.ADJ to adjust -V.