Descargar Imprimir esta página
Emerson SDN 5-24-100C Manual De Instrucciones

Emerson SDN 5-24-100C Manual De Instrucciones

Publicidad

Enlaces rápidos

Power Supplies
SDN 5-24-100C
SDN 5-24-100CX
Instruction Manual
Dimensions
1.97 in.
[50.0 mm]
Power Supply
LED Diagnostics
Loss
Low
High
LED
OK
No DC
of AC
AC
Load
Input
Green
---
Amber
Green
Green
Output
Green
---
Green
---
Amber
Alarm
---
---
---
Red
Amber
Technical Support
(800) 377-4384 • (847) 268-6651
solahd.technicalservices@emerson.com
www.solahd.com
Korean Manual is available on-line.
While every precaution has been taken to ensure accuracy and completeness in
this manual, Appleton Grp LLC d/b/a Appleton Group assumes no responsibility, and
disclaims all liability for damages resulting from use of this information or for any
errors or omissions. Specifications are subject to change without notice.
P/N: A272-154 Rev. 16 1/2018
© 2018 Appleton Grp LLC d/b/a
Appleton Group. All rights reserved.
Fuentes de Alimentación
SDN 5-24-100C
SDN 5-24-100CX
Manual de Instrucciones
Dimensiones
1.97 in.
[50.0 mm]
Power Supply
Diagnósticos LED
La
Alta
LED
OK
Perdida
CA Baja No CC
Carga
de CA
Entrada
Verde
---
Ámbar
Verde
Verde
Salida
Verde
---
Verde
---
Ámbar
Alarma
---
---
---
Rojo
Ámbar
Soporte técnico
(800) 377-4384 • (847) 268-6651
solahd.technicalservices@emerson.com
www.solahd.com
Aunque se ha tomado toda precaución para asegurar precisión e integridad en
esta información, Appleton Grp LLC d/b/a Appleton Group no asume ninguna
responsabilidad y deniega toda responsabilidad por daños que resulten por el uso de
esta información o por cualquier error u omisión. Las especificaciones están sujetas a
cambios sin previo aviso.
P/N: A272-154 Rev. 16 1/2018
© 2018 Appleton Grp LLC d/b/a
Appleton Group. All rights reserved.
Input
Nominal Voltage
Inrush Current
Power Factor (PFC)
Nominal Frequency
Output
Nominal Voltage
Current
Power
Power Boost
Hold-up Time
Tolerance
• Line Regulation
• Load Regulation
4.68 in. [118.8 mm]
• Time and Temperature
Drift
4.36 in. [110.8 mm]
Initial Voltage Setting
Ripple
Power Back Immunity
Parallel Operation
Overvoltage Protection
Environmental Data
Ambient Temperature
Corrosion Resistance
Degree of Protection
4.78 in. [121.6 mm]
Minimum Required Free
Space for Cooling
Weight
Over-
Too
Certifications
Hot
load
Hot
Green
Green
Green
Amber
Green
---
Red
Amber
Amber
IECEx
Emissions/Immunity
EN 61326-1; EN 55032 Class B; EN 55011 Group 1 Class B EN 61000-3-2,
EN 61000-3-3; EN 55024; EN 61000-6-1; EN 61000-6-2; EN 61000-6-3;
EN 61000-6-4; SEMI F47 Sag Immunity; KC KN32, KN35
Entrada
Voltaje Nominal
Arranque
Factor de Potencia (PFC)
Frecuencia Nominal
Salida
Voltaje Nominal
Corriente
Potencia
Elevación de Potencia
Tiempo de Retención
Tolerancia
• Regulación de Línea
• Regulación de Carga
• Desviación de Tiempo
y Temp
Ajuste Inicial de Voltaje
Rizo
4.68 in. [118.8 mm]
Inmunidad de Potencia
Inversa
4.36 in. [110.8 mm]
Operación Paralela
Protección de Sobre Voltaje >30.5 V CC, <33 V CC recuperación automática
Datos Ambientales
Temperatura Ambiente
Resistencia a la Corrosión
Grado de Protección
Espacio Requerido para
Enfriamiento
4.78 in. [121.6 mm]
Peso
Certificaciones
Sobre-
Muy
Caliente
carga
Caliente
Verde
Verde
Verde
Ámbar
Verde
---
Rojo
Ámbar
Ámbar
IECEx
Emisiones/Inmmunidad
EN 61326-1; EN 55032 Clase B; EN 55011 Grupo 1 Clase B EN 61000-3-2,
EN 61000-3-3; EN 55024; EN 61000-6-1; EN 61000-6-2; EN 61000-6-3;
EN 61000-6-4; SEMI F47 Inmmunidad a Picos
Technical Specifications
100–240 Vac, 100-340 Vdc
7 A typical, 23 A max
>0.92
50/60 Hz
24 Vdc (24-28 Vdc Adjustable)
5 A
120 W
1.5 x nominal current for 4 s
>20 ms (full load, 100 Vac input @ T
amb
95% output voltage
<± 2% overall
<0.5%
<0.5%
<1%
24.5 Vdc ± 1%
<50 mVpp
< 35 V: no damage, auto-recovery
Switch selectable
>30.5 Vdc, <33 Vdc auto recovery
Storage/Shipment: -40°C to +85°C
Full Nominal Load: -40°C to +60°C
Derate 120 W by 6 W per °C to 60 W from +60°C
to +70°C
Model SDN 5-24-100CX - Conformal coated to
meet G3 Harsh Rating per ISA 71.04 Group A.
IP20 (EN60529)
0.98 in. (25 mm) above and below, 0.39 in. (10 mm)
left and right, 0.59 in. (15 mm) in front
1.25 lb. (567 g)
UL 508/CSA C22.2 No. 107.1
UL 60950-1/CSA C22.2 60950-1
UL 60079-0, UL 60079-15,
CAN/CSA 60079-0, CAN/CSA 60079-15
Class I, Zone 2 AEx nA nC IIC T4 Gc
Class I, Zone 2 Ex nA nC IIC T4 U
IEC60950-1, EN60950-1
II 3 G Ex ec nC IIC T4 Gc DEMKO 11 ATEX1133501X
EN60079-0, EN60079-7, EN60079-15
Ex ec nC IIC T4 Gc IECEx UL15.0023X
IEC60079, IEC60079-7, IEC60079-15
2Ex nA nC IIC T4 Gc X
MSIP-REM-N4C-SDN5
Type Approval
Type Approval
Datos Técnicos
100–240 V CA, 100-340 V CC
Normal 7 A, máximo 23 A
>0.92
50/60 Hz
24 V CC (24-28 V CC Ajustable)
5 A
120 W
1.5 x la corriente nominal por 4 s
>20 ms (carga completa, entrada 100 V CA a tempera-
tura
mayor a 25°C) al 95% del voltaje de salida
ambiente
<± 2% en todo el rango
<0.5%
<0.5%
<1%
24.5 V CC ± 1%
<50 mVpp
< 35 V: no implica daño, autorecuperación
Interruptor seleccionable
Almacenamiento/Embarque: -40°C to +85°C
Carga nominal completa: -40°C to +60°C
Reduzca la capacidad normal de 120 W por 6 W por el
°C a 60 W a partir del +60°C a +70°C
El modelo SDN 5-24-100CX está recubierto con un
revestimiento de conformación que satisface un nivel
G3 para condiciones ambientales difíciles de acuerdo
con la norma ISA 71.04 Grupo A.
IP20 (EN60529)
0.98 in. (25 mm) por encima y por debajo, 0.39 in. (10
mm) izquierda y derecha, 0.59 in. (15 mm) por delante
1.25 lb. (567 g)
UL 508/CSA C22.2 No. 107.1
UL 60950-1/CSA C22.2 60950-1
UL 60079-0, UL 60079-15,
CAN/CSA 60079-0, CAN/CSA 60079-15
Class I, Zone 2 AEx nA nC IIC T4 Gc
Class I, Zone 2 Ex nA nC IIC T4 U
IEC60950-1, EN60950-1
II 3 G Ex ec nC IIC T4 Gc DEMKO 11 ATEX1133501X
EN60079-0, EN60079-7, EN60079-15
Ex ec nC IIC T4 Gc IECEx UL15.0023X
IEC60079, IEC60079-7, IEC60079-15
2Ex nA nC IIC T4 Gc X
MSIP-REM-N4C-SDN5
Aprobación de Tipo
Aprobación de Tipol
Installation Specifications
Overcurrent Protection
Input: Internally fused.
Output: Outputs are capable of providing high currents for short periods of time for
inductive load startup switching.
Relay
N.O. contact rated 200 mA/50 Vdc.
Connections
An accessible disconnect device shall be installed external to the equipment.
Use copper conductors only, 60/75°C
Input: Screw terminals. Connector size range: 16–10 AWG (1.5–6 mm
stranded conductors. Screw torque: 4.4-6.0 lb-inch (50-73 N-cm).
Output: Two terminals per output. Connector size range: 16–10 AWG (1.5–6 mm
for solid or stranded conductors. Screw torque: 4.4-6.0 lb-inch (50-73 N-cm).
+25°C) to
Use only one copper wire per terminal for input and output.
Non-ratcheting torque driver recommended.
Note: During power supply replacement, ensure wiring connections are properly
terminated by verifying that terminal ID locations are the same. The location and
arrangement of the terminals can vary between manufacturer and model number.
Safety
The power supplies should meet the following conditions for safe use when installed
in a Class I, Zone 2, Groups IIC Hazardous Location:
(1) The equipment shall only be used in an area of not more than pollution degree 2,
as defined in IEC 60664-1.
(2) The equipment shall be installed in an enclosure that provides a degree of
protection not less than IP54 in accordance with IEC 60079-0.
(3) The operating temperature class (T-code) of this device was determined to be
T4.
Warning — Explosion Hazard — Do not disconnect the equipment while the circuit
is live or unless the area is known to be free of ignitable concentrations.
Warning — Explosion Hazard — Do not open the unit. Do not substitute
components. Do not replace fuse.
Warning — Exposure to some chemicals may degrade the sealing properties of
materials used in the sealed relay device.
The power supplies should meet the following when installed in an ordinary locations
environment: Install in a controlled environment.
DIN Rail Mounting
Simple snap to DIN TS35/7.5 or TS35/15 rail system.
1. Tilt unit as illustrated.
2. Put unit onto the DIN rail.
3. Push unit downward until it stops.
4. Push at the lower front edge to lock.
5. Gently shake the unit to ensure that it is secure.
Especificaciones de Instalación
Protección de Sobreintensidad
Entrada: Fusibles internos.
Salida: Las salidas son capaces de proporcionar altas corrientes por períodos cortos
de tiempo para arranque de carga inductiva o conmutación.
Relevo
N.O. contacto valoró 200 mA/50 V CC.
Conexiones
Un dispositivo accesible de desconexión será instalado externo al equipo.
Utilizar sólo conductor de cobre, 60/75ºC.
Entrada: terminales tipo tornillo Rango de tamaños de conectores: 1,5–6 mm
conductores unifilares o trenzados. Torque de tornillo: 50-73 N-cm
Salida: dos terminales por salida. Rango de tamaños de conectores: 1,5–6 mm
conductores unifilares o trenzados. Torque de tornillo: 50-73 N-cm
Se recomienda un conductor de torque sin ajuste.
Nota: Durante la sustitución del suministro de energía, asegúrese de que las conex-
iones de cableado estén correctamente finalizadas, verificando que las ubicaciones
de los ID de los terminales sean las mismas. La ubicación y la disposición de los
terminales pueden variar según el fabricante y el número de modelo.
Seguridad
Las fuentes de alimentación deben cumplir las siguientes condiciones
para un uso seguro cuando se instala en un área peligrosa de clase I,
zona 2, grupos IIC:
(1) El equipo solo se debe usar en un área de un grado de polución no mayor que 2,
como se define en IEC 60664-1.
(2) El equipo se debe instalar en un gabinete que proporcione un grado de protección
no menor que IP54 de acuerdo con IEC 60079-0.
(3) La clase de temperatura de operación (código T) de este dispositivo es T4.
Advertencia — Peligro de Explosión — No desconecte el equipo si el circuito está
conectado, exceptuando si se sabe que no existen concentraciones inflamables en
el área.
Advertencia — Peligro de Explosión — No abra la unidad. No sustituya
componentes. No sustituya el fusible.
Advertencia — La exposición a ciertas sustancias químicas podría degradar las
propiedades selladoras de los materiales utilizados en el relé sellado.
Las fuentes de alimentación deben cumplir con lo siguiente cuando se instalen en un
entorno de áreas ordinarias: instalar en un entorno controlado.
Montaje en Riel DIN
Se adapta de manera sencilla en sistema Riel DIN TS35/7.5 ó Sistema TS35/15.
1. Incline la unidad como se ilustra.
2. Póngala sobre el Riel DIN.
3. Empuje hacia abajo hasta que se detenga.
4. Empuje de la parte baja del frente para asegurar.
5. Mueva la unidad ligeramente para verificar está segura.
) for solid or
2
)
2
para
2
para
2

Publicidad

loading

Resumen de contenidos para Emerson SDN 5-24-100C

  • Página 1 24 Vdc (24-28 Vdc Adjustable) An accessible disconnect device shall be installed external to the equipment. Current Use copper conductors only, 60/75°C SDN 5-24-100C Input: Screw terminals. Connector size range: 16–10 AWG (1.5–6 mm ) for solid or Power 120 W stranded conductors.
  • Página 2 Un dispositif de déconnexion accessible doit être installé à l’extérieur de l’équipement. Courant Utiliser seulement conducteurs en cuivre, 60/75 °C Puissance SDN 5-24-100C 120 W Entrée : bornes à vis. Plage de calibre des connecteurs : 1,5 à 6 mm pour les conducteurs pleins ou câblés.

Este manual también es adecuado para:

Sdn 5-24-100cx