Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
C
o
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V and 24V
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
Output
SLS-05-060-1T
+5V / 6.0 A
SLS-12-034-T
+12V / 3.4 A
SLS-24-024-T
+24V / 2.4 A
Operating Temperature Range
0 to +50
o
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Per MIL-STD-810C, Method 516
Shock
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
EMI/RFI
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Cooling
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Multi Input (all units)
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
Transient Response Time
50 µsec at 50% load changes for outputs rated up to 6A
Units are not fused internally. For safe operation, user must provide input line
Fuse Requirements
fuse as per values given in table.
Line Regulation
0.05% for +/- 10% change
Load Regulation
0.05% for 50% change
Ripple
3.0 mV maximum peak-to-peak
DC Output Adjustment Range
+/- 5% minimum
All 5 volt outputs include built-in OVP as standard (setting is 6.2 V +/- 0.4 V).
Overvoltage Protection
OVP is optionally available on other outputs.
Remote Sensing
All units listed have remote sensing capability.
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-05-060-1T, SLS-12-034T,
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
C (Derate to 40% at +70
C)
o
C
o
Input Specifications
Output Specifications
Input AC Connections (See Case B)
SLS-24-024T
For use
100 VAC
120 VAC*
220 VAC
230 VAC
240 VAC
Mechanical Dimensions: inches (mm)
CASE B1
+OUT
+S
-S
-OUT
4
2
3
1
5
CASE B2
-OUT
-S
+S
+OUT
4
2
3
1
5
Use Case B1 Output Configuration for SLS-05-060-1T and SLS-12-034T.
Note: The SLS models DC output can be adjusted with R10 V. ADJ.
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
at:
Connect
Apply AC to:
1-3, 2-4
1 & 5
1-3, 2-4
1 & 4
2-3
1 & 5
2-3
1 & 4
2-3
1 & 4
*Note: Unit is shipped for 120V input from factory.
1.28" (32.5)
4.87" (123.5)
0.252" (6.4)
4.118" (104.6)
R8 I.LIM
.39"
(10)
R10 V.ADJ
0.188"
0.433" (11)
(4.8)
° MTG HOLE S (8 PLACES )
WEIGHT: 4 LBS.(1.8
0.72" (18.3)
Case B
Use Case B2 Output Configuration for SLS-24-024T.
R8 I. LIM is factory set and should not be adjusted by users.
Visit our website at www.solaheviduty.com
Primary Fuse
(SLS-05-0601T)
(SLS-12-034T)
(SLS-24-024T)
1.6A / 125V
1.6A / 125V
0.8A / 250V
0.8A / 250V
0.8A / 250V
0.72" (18.3)
.450" (11.5)
MAX
PEM NUT HOLES
6-32 MTG (4 PLACES)
KG
)

Publicidad

loading

Resumen de contenidos para Emerson SOLA/HEVI-DUTY SL Serie

  • Página 1 Linear Open Frame DC Power Supplies Silver Line Instruction Manual Models: SLS-05-060-1T, SLS-12-034T, Input AC Connections (See Case B) SLS-24-024T Primary Fuse Features (SLS-05-0601T) For use Connect Apply AC to: • Easy installation with strip terminal • Multi-Tap AC Inputs (SLS-12-034T) •...
  • Página 2 Serie SL - Lineales de Salida Sencilla & Múltiple Manual de la Instrucción Modelos: SLS-05-060-1T, SLS-12-034T, Entrada AC Conexiones (See Caja B) SLS-24-024T El fusible primario Características Para el (SLS-05-0601T) • Terminales de conexión fáciles de instalar. • Multi-Tap AC Las Entradas Conecte Aplique AC a: uso en:...

Este manual también es adecuado para:

Sola/hevi-duty sls-05-060-1tSola/hevi-duty sls-12-034tSola/hevi-duty sls-24-024t