TROUBLESHOOTING

F A U L T
Water drips out
when moving unit
Unit does not op-
erate
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor.
SPECIFICATIONS
Name
Filter
Dimensions (W × H × D)
Weight (w/ cord & hose)
Amps
Power
Air movement
Water removal
Operating temperature range
Safety
Specifications are subject to change without notice. Some values
may be approximate.
07-02183A EB140
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Room air is dry.
Room temperature is too low.
Air filter is full.
Heat exchange block and/or
coils are clogged.
EB140 Dehumidifier
EBF140
12.5 × 17.6 × 21.5 in.
31.8 × 44.7 × 130.8 cm
65 lbs. | 29.5 kg
6.2 amps at 80°F/60% RH
115V / 60Hz
180 CFM | 5.4 CMM
80 pts/day | 37.9 L/day
at 80°F/60% RH
134 pts/day | 63 L/day
at 90°F/90% RH
45–100°F | 7–38°C
Certified to CSA Std C22.2 No. 92
S O L U T I O N
Purge unit before moving. See "Before Moving Unit After
Use," p. 5.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Clean or replace as necessary.
Check heat exchange block and coils. Clean as necessary.
PARTS INCLUDED
20 ft. (6 m) of drain hose with quick-connect fitting.
25 ft. (7.6 m) detachable power cord.
1 disposable air filter (reorder EBF140)
OPTIONAL
Duct Attachment Kit (EBDK)
Hanging Kit (EBHK)
FOR PARTS AND SERVICE CALL YOUR LOCAL DIS-
TRIBUTOR or EnviroBoss at 800-932-3030. www.Envi-
roBoss.com
For proper disposal, this unit should be taken to a recycler
licensed to process refrigeration equipment.