Figure 4 Drilling (Not To Scale) - Federal Signal Spire 100 Beacon Manual De Instrucciones

Ocultar thumbs Ver también para Spire 100 Beacon:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Maintenance Instructions
the inner circle in Figure 3). The holes for the #10 self-
tapping screws are on a 4-inch diameter (where the lines
intersect the middle circle in Figure 3). The 4-inch pattern is
the preferred pattern for permanent mounting.
If one of the optional mounting flanges is to be used,
three #10 screws are on a 6.00-inch circle (where the lines
intersect the outer circle in Figure 3).
Drill three 0.177-inch diameter holes for the #8 screws, or
three 0.201-inch diameter holes for the #10 screws.
2. Scribe a hole for the wires or an installer-supplied bushing at
the center of the screw pattern.
12

Figure 4 Drilling (Not to scale)

6.00"
4.00"
2.75"
120.0°
120.0°
Federal Signal www.fedsig.com
100 Beacon
Spire
®

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Baliza spire 100 led

Tabla de contenido