High voltages are present inside the light assembly. Wait at least 5 minutes after disconnecting
power before servicing this unit.
Listed below are some important safety instructions and precautions you should follow:
Read and understand all instructions before operating this system.
Any maintenance to the light system must be done with the power turned off.
Any maintenance to the light system must be performed by a trained electrician in
accordance with all applicable national and local codes in the country of use.
Never alter the unit in any manner. Safety of the unit may be compromised if additional
openings or other alterations are made.
The nameplate should not be obscured, it contains cautionary and/or other information
of importance to maintenance personnel. Ensure the nameplate remains readable if the
housing's exterior is painted.
If dome is damaged in any way, it MUST be replaced.
After performing any maintenance, test the light system to ensure that it is operating
properly.
Failure to follow all safety precautions and instructions may result in property damage, serious injury,
or death to you or others.
A.
Flash Tube Replacement.
As strobe lights are used, the flash tubes begin to darken, causing the light output to decrease.
This darkening is characteristic of flash tubes. The darkening will begin near the base of the tube and
progress upward. In addition, as flash tubes age, they may have a tendency to misfire (not fire periodically).
After extended operation, occasionally check for flash tube degradation. Should the flash tube
misfire, have a noticeable decrease in light output, glow continuously or darken to a point beyond that
shown in Figure 2 — it should be replaced.
High voltages are present inside the light assembly. Wait at least 5 minutes after shutting off the
power before servicing this unit.
To change the flash tube, proceed as follows:
1.
Disconnect power.
2.
Loosen the setscrew, located on the globe-and holder assembly.
3.
Grasp the top of the dome and push down while turning the dome counterclockwise
approximately 3/4-inch (19 mm).
Effectiveness of hazardous location enclosure must be maintained. Do not damage globe or
threads while disassembling or reassembling unit. Lubricated joints exposed for long periods of
time may attract small particles of dirt or other foreign materials. Body and cover joints should
be reassembled immediately.