Using Your Bath (cont.)
As the pump/motor turns on and water begins to circulate, the light will change to solid green, and
will stay on as long as the overflowing bath is running.
Verify that the indicator light for the heater is on when the overflowing bath is in operation. This
indicator light is located on the underside of the heater box, and is near the subfloor at the pump
end of overflowing bath. If the light is not on when the overflowing bath is running, press the reset
button located to the right of the indicator light on the heater box.
Press the "On/Off" control switch again to turn off the overflowing bath. The orange light in the
"On/Off" switch will temporarily turn on to indicate the end of the operating mode. The green light
in the "On/Off" control switch will then start to blink automatically until the overflowing bath is
drained below the overflow channel sensors or restarted.
NOTE: A built-in timer automatically stops the bath after approximately 20 minutes of operation.
15. Chromatherapy Light Operation (if equipped)
NOTE: These directions pertain to the use of the mounted control pad only. For more information, see the
"Test the Remote Control" section.
If the chromatherapy lights are turned off, press the button on the control pad (located on the
opposite side of the overflowing bath. The chromatherapy lights will begin to cycle through each of
the colors (sweep mode).
When the chromatherapy lights are in sweep mode, you can lock in one color light by pressing the
control button.
When an individual color is locked in, press the control button to turn the chromatherapy lights
off.

Troubleshooting

NOTICE: This section is for general aid only. A Kohler Co. Authorized Service Representative or
qualified electrician should correct any electrical problems. For warranty service, call 0-800-4-KOHLER.
NOTE: The product model number is printed on a label on the pump side of the whirlpool.
NOTE: For service parts information, visit your product page at www.kohler.com.br.
Symptoms
Green light in "On/Off"
1.
control switch flashes
before the bathing well is
full of water.
2.
Product does not start.
1019731-BR2-A
Probable Causes
A. Spout fills directly into overflow
channel.
B. One or both butterfly valves do
not work.
C. Control does not work.
A. No power to unit.
B. Water does not cover the overflow
channel sensors.
English-16
Recommended Action
A. Adjust/reinstall the spout to fill
directly into the bathing well.
Refer to the installer/dealer.
B. Check the butterfly valve wiring
or replace the butterfly valves.
Refer to the installer/dealer.
C. Check the wiring or replace the
control. Refer to the
installer/dealer.
A. Turn on the power to the unit, or
correct the source of the power
loss. Refer to the installer/dealer.
B. Fill the bathing well until water
flows over the bathing well rim,
into the overflow channel, and
covers the overflow channel
sensors. Suggested fill level is to
the drain overflow.
Kohler Co.