Open and then close the gate leaf completely, checking there is no strong friction during the movement.
Insert the mechanical stops for opening and closing.
Before installing the automation, check that:
- the hinges or pivots are sturdy and efficient and there is no strong friction
- the length of the power cable between the actuator and the control unit is no more than 15 metres
- there are the mechanical stops for opening and closing which are properly secured
Installing the actuator:
1-
Insert the actuator into the foundation box
2-
Tighten the 4 screws making sure that the output shaft correctly enters the bush of the gate leaf driving unit. In order to facilitate this operation, move the
gate leaf manually until the shaft is able to enter the bush.
3-
Secure the 4 screws.
Unlock the actuator: In the event of mains power failure, the back-up battery ensures the operation of the automatic gate system for a limited period. If the
battery is discharged or not installed, manually unlock the actuator using the unlocking lever.
1. Remove the plastic cap
2. Insert the lever and rotate it by 90° until the gate leaf is freed
3. The gate leaf is unlocked and opens with a slight pressure.
4. Remove the lever and put the cap back on.
5. Repeat operations 1 to 4 for the second gate leaf, if present
N.B.: If the gate leaf exceeds 1.6 m in length it is necessary to install the electrical lock.
16
1. Bush
2. Central ring nut
3. Foundation box
4. Cover
5. Gate leaf driving unit with unlocking