APPARECCHIATURA ELETTRONICA ASX03I
TRASFORMATORE
BANCO
FUSIBILI
F1
TRS
160mA
F2
SLR
250mA
F3
ENG
4A
F4
24V
500mA
MORSETTI
ESTRAIBILI
1-2
11-12
13-23
18-19
14-15
7
8
9
43
8-10
PROGRAMMI E FUNZIONI
DIP
FUNZIONE
1
2
LAVORO
OFF
OFF
AUTOTEST
OFF
ON
UOMO PRESENTE
ON
OFF
SEMIAUTOMATICO
ON
ON
AUTOMATICO
3
SEQUENZA AI COMANDI START
OFF
APERTURA; SOLO A FCA CHIUSURA; IN CHIUSURA
ARRESTO E APERTURA ( PROG. CONDOMINIALE ).
ON
APERTURA, STOP, CHIUSURA, STOP, APERTURA ......
4
PRELAMPEGGIO
OFF
ESCLUSO
ON
INSERITO ( 2.5" PRIMA DI OGNI FASE DI MOTO )
5
FOTOCELLULA
OFF
INTERVIENE SOLO IN CHIUSURA ARRESTANDO E
RIAPRENDO SINO A FCA.
ON
SIA IN APERTURA CHE IN CHIUSURA ARRESTA
E, SOLO SE LIBERATA, RIAPRE.
6
REVERSER
OFF
ESCLUSO
ON
INSERITO
7
INVERSIONE SENSO DI MARCIA
OFF
MARCIA DIRETTA
ON
MARCIA INVERSA
8
NON UTILIZZATO
OFF
MANTENERE NECESSARIAMENTE IN OFF
BANCO
RELE'
F1
F2
LINEA MONOFASE 230Vac
LAMPEGGIATORE
CONTATTO AUSILIARIO
CONTATTO NC FOTOCELLULA
UTENZA 24Vac MAX. 300mA
CONTATTO NC DI STOP
COMUNE GND DEI PULSANTI
CONTATTO NA DI START
CONTATTO NA DI START PEDONALE
LAMPADA SPIA 24Vac- 3W
F3
F4
LED LGT
DOPO OGNI CAMBIAMENTO NELLA CONFI-
GURAZIONE DEI DIP-SWITCH, PREMERE IL
TASTO DI RESET PER IMPOSTARE IL
COMANDI E CONTROLLI
TRIMMER
TEMPO DI
PAUSA
(2 ÷ 120")
LED LGT
- 4 -
MICROPROCESSORE
PROGRAMMAZIONE
CONNETTORE
TRIMMERS
CONNETTORE
REVERSER
LEDS DI STATUS
ATTENZIONE
NUOVO PROGRAMMA.
DIP-SWITCH DI
PROGRAMMA
TRIMMER
TEMPO DI LAVORO (2 ÷ 80" )
LEDS DI STATUS
FCA
FINECORSA APERTURA
FCC
FINECORSA CHIUSURA
LUX
FOTOCELLULA
STP
PULSANTE STOP
RUN
PULSANTE START
PAR
PULSANTE START PEDONALE
REV
REVERSER
TASTO DI
RESET
DIP-SW. DI
RADIO