TRANSFORMER
FUSE
GROUP
F1
TRS
160mA
F2
SLR
250mA
F3
ENG
4A
F4
24V
500mA
REMOVABLE
TERMINALS
1-2
11-12
13-23
8-10
14-15
18-19
9
7
43
8
PROGRAMS AND FUNCTIONS
DIP
FUNCTION
1
2
OPERATION
OFF
OFF
AUTOTEST
OFF
ON
MANUAL
ON
OFF
SEMI-AUTOMATIC
ON
ON
AUTOMATIC
3
SEQUENCE FOR START COMMANDS
OFF
OPENING; ONLY TO FCA CLOSING; IN CLOSING,
STOP AND REOPEN (PROG. FOR BLOCK OF FLATS).
ON
OPENING, STOP, CLOSING, STOP, OPENING......
4
PRE-FLASHING
OFF
DEACTIVATED
ON
ACTIVATED ( 2.5" BEFORE EACH PHASE OF MOVEMENT)
5
PHOTOCELL
OFF
INTERVENES ONLY IN CLOSING BY STOPPING AND
REOPENING UP TO FCA.
ON
IN BOTH OPENING AND CLOSING, STOPS AND,
ONLY IF FREE, REOPENS.
6
REVERSER
OFF
DEACTIVATED
ON
ACTIVATED
7
INVERSION OF DIRECTION
OFF
FORWARD DRIVE
ON
REVERSE DRIVE
8
NOT USED
OFF
ALWAYS KEEP AT OFF
ELECTRONIC EQUIPMENT ASX03I
RELAY
BANK
F1
F2
230 Vac SINGLE-PHASE LINE
FLASHER
AUX. CIRCUIT BREAKER
24Vac/3W INDICATOR LIGHT
24Vac TX PHOTOCELL
RX PHOTOCELL N.C. CONTACT
START BUTTON, N.O. CONTACT
STOP BUTTON, N.C. CONTACT
PEDESTRIAN BUTTON, N.O. CONTACT
PUSHBUTTON GND COMMON CONTACT
F3
F4
LGT LED
AFTER CHANGING DIP-SWITCH SETTINGS,
PRESS THE RESET BUTTON TO ENTER AND
STORE THE NEW CONFIGURATION.
COMMANDS AND CONTROLS
TRIMMER
PAUSE TIME
(2 - 120")
LGT LED
- 8 -
MICROPROCESSOR
PROGRAMMING
DIP-SWITCH
RADIO
CONNECTOR
TRIMMERS
REVERSER
CONNECTOR
STATUS LEDS
IMPORTANT
PROGRAMMING
DIP-SWITCH
TRIMMER OPERATING
TIME (2 - 80")
STATUS LEDS
FCA
OPENING TRAVEL STOP
FCC
CLOSING TRAVEL STOP
LUX
PHOTOCELL
STP
STOP BUTTON
RUN
START BUTTON
PAR
PEDESTRIAN BUTTON
REV
REVERSER
RESET
BUTTON