Battery Charging; Initial Operation - Bosch GLM 100 C Professional Manual Original

Ocultar thumbs Ver también para GLM 100 C Professional:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-2166-001.book Page 11 Wednesday, March 5, 2014 2:16 PM
1
Double indirect height measurement
2
Indirect length measurement
1
Timer Function
Wall-surface measurement
Grade Measurement
g Battery charge-control indicator
h Laser, switched on
i Measurement reference level
k Temperature warning
l Bluetooth® switched on
Bluetooth® activated, connection established
Bluetooth® activated, no connection estab-
lished
m Charging procedure
n Slow charging procedure
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG, Inc. and any use of such
marks by Robert Bosch Ltd. is under license.
Assembly

Battery Charging

 We recommend using chargers from the Bosch acces-
sory range.
 Observe the mains voltage! The voltage of the power
source must correspond with the data on the type plate of
the battery charger.
Note: The battery is supplied partially charged. To ensure full
battery capacity, completely charge the battery before using
for the first time.
The lithium-ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
When the bottom segment of the battery charge-control indi-
cator g flashes, only a few more measurements can be carried
out. Charge the battery.
When the frame around the segments of the battery charge-
control indicator g flashes, measurements are no longer pos-
sible. Continued use of the measuring tool is only possible for
a short period (e.g., for checking entries in the measured-val-
ue list, performing a calculation, etc.). Recharge the battery.
The charge procedure begins as soon as the mains plug of the
battery charger is plugged into the socket outlet and the
charge connector 23 is plugged into socket 15.
Bosch Power Tools
The battery charge-control indicator g indicates the charging
progress. During the charging procedure, the segments flash
one after the other. When all segments of battery charge-con-
trol indicator g are displayed, the battery is completely
charged.
Disconnect the battery charger from the mains supply when
not using it for longer periods.
Additionally, the battery can also be recharged via a USB port.
For this, connect the measuring tool to a USB port using the
micro USB cable. In USB operation (recharging, data trans-
mission), the charging duration n can be significantly pro-
longed.
The measuring tool cannot be used independently during the
charging procedure. Usage is possible only in combination
with a USB connection and the available software.
The Bluetooth® function switches off during the charging pro-
cedure. Existing connections to other devices are interrupt-
ed. This can lead to data loss.
 Protect the battery charger against moisture!
Notes for Optimum Handling of the Battery in the Measur-
ing Tool
Store the measuring tool only within the allowable tempera-
ture range, see "Technical Data". As an example, do not leave
the measuring tool in a vehicle in summer.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
Observe the notes for disposal.
Operation

Initial Operation

 Do not leave the switched on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
 Protect the measuring tool against moisture and direct
sun light.
 Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
 Avoid heavy impact to or falling down of the measuring
tool. After severe exterior effects to the measuring tool, it
is recommended to carry out an accuracy check (see "Ac-
curacy Check and Calibration of the Grade Measurement"
and "Accuracy Check of the Distance Measurement" on
page 17) each time before continuing to work).
English | 11
2 609 141 158 | (5.3.14)