Descargar Imprimir esta página
Eaton PORTFOLIO C4013 Instrucciones De Instalación
Eaton PORTFOLIO C4013 Instrucciones De Instalación

Eaton PORTFOLIO C4013 Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

ADP140647
Installation Instructions – C4013 and C4018 Commercial Recessed
Compact Fluorescent Rough-In
Instructions d'installation – pose préliminaire du luminaire
fluorescent compact encastré commercial C4013 et C4018
Instrucciones de instalación de luminarias fluorescentes compactas
empotradas de uso comercial para áreas ocultas C4013 y C4018
IMPORTANT: Read carefully before installing fixture.
Retain for future reference.
WARNING
Risk of Electrical Shock! Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Fire! Do not install insulation within 3 inches
(76 mm) of any part of the luminaire (fixture) or in a
way that may entrap heat.
N
otee:
This fixture should be supported by main runners or
other structure that is capable of supporting fixture
weight of 10 Ibs.
INSTALLATION
To Install Rough-In Section
1.
Install fixture into ceiling cavity using 1/2" electrical
conduit. Use 3/4" channel, 1-1/2" channel,
1/8" x 1/2" bar stock, or T-bar fasteners as mounting
rails (furnished by others) by inserting them through
hanger brackets at both ends.
2.
Adjust hanger adjustment screws so bottom of plaster
ring is flush with finished ceiling line. Hanger bracket
is reversible for a total adjustment of 5" . (Figure 1.)
3.
Remove one of the junction box covers. Connect
supply lead wires to lead wires of ballast per wiring
diagram and in accordance with your local electrical
code(s) or N.E.C.
IMPORTANT SAFEGUARDS: When using electrical
equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW THE SAFETY INSTRUCTIONS
1.
This unit is for recessed mounting only. Do not use in
hazardous locations nor near gas or electric heaters.
2.
Do not use this equipment for other than the
intended use.
3.
Install only in accordance with National Electrical
Code and local regulatory agencies' requirements.
WARNING
Installation and servicing to be performed only
by qualified personnel. If not qualified, consult an
electrician.
2
1
Spring
Settings
Figure 1.
TM
INS #
Hanger Bar
Adjustment
Screw

Publicidad

loading

Resumen de contenidos para Eaton PORTFOLIO C4013

  • Página 1 INS # ADP140647 Installation Instructions – C4013 and C4018 Commercial Recessed Compact Fluorescent Rough-In Instructions d’installation – pose préliminaire du luminaire fluorescent compact encastré commercial C4013 et C4018 Instrucciones de instalación de luminarias fluorescentes compactas empotradas de uso comercial para áreas ocultas C4013 y C4018 IMPORTANT: Read carefully before installing fixture.
  • Página 2 Figure 3. Wiring Diagram 4030/1 13W Quad Fixture Trim Lamp Setting C4018 4080/1 18W Triple 4050/1 18W Triple 4010/1 18W Triple 4020/1 18W Triple 4030/1 18W Triple Installation Instructions - C4013 and C4018 Commericial Recessed Compact Fluorescent Rough-In 702980 ADP140647 www.eaton.com...
  • Página 3: Mesures De Protection Importantes

    (2) vis dans les fentes. C4018 4080/1 Triple 18W 4050/1 Triple 18W 4010/1 Triple 18W 4020/1 Triple 18W 4030/1 Triple 18W Instructions d’installation – pose préliminaire du luminaire fluorescent compact encastré commercial C4013 et C4018 702980 ADP140647 www.eaton.com...
  • Página 4 ROUGE ROUGE BLEU CHAUD – NOIR BLEU NEUTRE – BLANC BALLAST Figure 3. Figure 2. Schéma lèche-mur Schéma de câblage Instructions d’installation – pose préliminaire du luminaire fluorescent compact encastré commercial C4013 et C4018 702980 ADP140647 www.eaton.com...
  • Página 5: Instalación

    4080/1 18 W triple 4050/1 18 W triple 4010/1 18 W triple 4020/1 18 W triple 4030/1 18 W triple Instrucciones de instalación de luminarias fluorescentes compactas empotradas de uso comercial para áreas ocultas C4013 y C4018 702980 ADP140647 www.eaton.com...
  • Página 6 AZUL VIVO - NEGRO AZUL NEUTRO- BLANCO BALASTO Figura 2. Diagrama del bañador de pared Figura 3. Diagrama de cableado Instrucciones de instalación de luminarias fluorescentes compactas empotradas de uso comercial para áreas ocultas C4013 y C4018 702980 ADP140647 www.eaton.com...
  • Página 7 All trademarks are property Eaton’s Cooper Lighting Business of their respective owners. 1121 Highway 74 South Peachtree City, GA 30269 Eaton est une marque de commerce Cooperlighting.com déposée. Toutes les autres marques de commerce sont la propriété de leur © 2014 Eaton propriétaire respectif.

Este manual también es adecuado para:

Portfolio c4018