Installation Instructions – C4013 and C4018 Commercial Recessed Compact Fluorescent Rough-In
To Install Trims
1.
Adjust the two springs as shown in illustration.
(Figure 1.) Refer to corresponding Spring Setting Chart
for proper adjustment.
2.
Attach trim to socket assembly with (2) screws through
keyslots.
To Clean Trims
1.
Gently wipe with a soft, clean, dry lint-free cloth to
remove dust.
2.
Wipe with a mild detergent solution on a soft, clean
cloth to remove fingerprints and stains.
3.
Rinse with clean, soft water and dry with lint-free cloth.
N
otee:
For Wall Wash Installation, housing is to be installed
with one of (4) sides (A,B,C,D) facing the wall. Wall
wash trims can be oriented with stepped reflector
facing wall. Use secondary screws supplied with trim
for alternate orientation. It may be necessary to fully
tighten screws on housing first. Install screws 180°
apart. (Figure 2.)
Spring Setting Chart
Fixture
Trim
C4013
4080/1
4050/1
4010/1
4020/1
4030/1
Fixture
Trim
C4018
4080/1
4050/1
4010/1
4020/1
4030/1
Installation Instructions - C4013 and C4018 Commericial Recessed Compact Fluorescent Rough-In
2
Lamp
Setting
13W Quad
2
13W Quad
1
13W Quad
1
13W Quad
1
13W Quad
1
Lamp
Setting
18W Triple
2
18W Triple
1
18W Triple
1
18W Triple
1
18W Triple
1
702980
ADP140647
A
D
C
Figure 2.
Wall Wash Diagram
RED
HOT - BLACK
NEUTRAL - WHITE
Figure 3.
Wiring Diagram
www.eaton.com
B
RED
BLUE
BLUE
BALLAST