Mask-Hood
•
Grab mask-hood by the LGDV. •
•
Slip the mask-hood on from
back of the head and tighten
with straps and neck string.
•
To activate LGDV, inhale once
forcefully or push the flush
button.
(6)
Close and adjust waist belt if applicable.
(7)
Escape immediately and return to uncontaminated and non-
hazardous area.
(8)
Check pressure gauge regularly.
(9)
Remove device only in an uncontaminated area.
After use
(1)
Remove mask-hood or full face mask.
(2)
Push the red stand-by button of the LGDV to switch off the air
flow.
(3)
Put device components back into carrying bag.
(4)
Hand over device to service.
Do not throw off the compressed air breathing apparatus.
This
could
compressed air could escape suddenly.
This could cause fatal injury to you or to any bystanders.
After use the device has to be serviced to be ready to
operate!
GB
WARNING
damage
the
WARNING
Full Face Mask
Grab full face mask by the
LGDV.
•
Press full face mask on face to
create a tight face seal.
•
To activate LGDV, inhale once
forcefully or push the flush
button.
•
Quickly complete donning full
face mask.
valve
and
Order No.: 10152756/00
any
remaining