6020 - 6023
The instruction manual is downloadable from the site www.
vimar.com
Description
PETRARCA series monitor Art. 6020 (6000), 6023 (6003)
can work in conjunction with interphones 6200 - 6201 - 6204
for video door entry systems series "SOUND SYSTEM",
"C.A. CALL", "DIGIBUS" and with telephone type 3562. In
addition, the monitor may be installed on its own using the
corresponding accessories.
Technical characteristics of Art. 6020
- Slim-line surface wall-mounted monitor B/W with 3,5" flat
screen.
- Minimum supply voltage: 15 Vdc (maximum 20 Vdc)
- Video signal standard: CCIR with 625 lines and 50
frames (EIA standard available on request)
- Passband: 4 MHz
- Video signal input voltage: 1Vpp via 75 Ohm coax cable
or twisted pair.
Technical characteristics of Art. 6023
- Slim-line surface wall-mounted monitor with colour
screen 3,5".
- Minimum supply voltage: 15 Vdc (maximum 20 Vdc)
- Video signal standard: PAL
- Video signal input voltage: 1 Vpp via 75 Ohm coax cable.
Fitting the monitor with interphone
Fig.1
Mount the bracket, part No. 6145, on the wall at a
height of approximately 1.40 m from the floor.
Fig.2, 3 Open the interphone, split the cover from the bot-
tom making pressure onthe lower side of the cover
Fig.4
Inside the interphone, fit the connection card sup-
plied with the monitor Petrarca, and connect the
card to the interphone by means of connectors
CN2 (card) and CN1 (interphone).
Fig.5
Fit the base of the interphone on the left-hand side
of the bracket by inserting it into the appropriate
seats and pulling it downwards until it locks com-
pletely into position.
Make the connections to the terminals of the inter-
phone and the monitor card.
Fig.6
Connect the cabling of the monitor to the connec-
tion card by means of connector CN1 on the card.
Fit the monitor by positioning it in the appropriate
seats and pulling it downwards until it locks com-
pletely into position.
Fig.7
Close the interphone by fastening the casing to the
top of the base and press the bottom of the casing
until it clicks into place. To remove the interphone
or monitor from the bracket, press the safety tab
with a screwdriver and pull out in the direction of
the arrows.
Installation of monitor and telephone
Fig. 8
Embed 3 module back box Art. 7149 so that it is
flush-mounted on the wall about 1.45 m from the
ground.
Fig. 9
Attach mounting bracket Art. 6146 using the 4
screws provided and keeping flush-mounted back
box at the right hand side of the plate. Fix the con-
necting circuit (provided with the monitor) on the
plastic seat provided with the plate.
Fig. 10 Carry out the connection of the installation to the
monitor connection circuit. Insert the telephone
cable (provided) in the connector in the socket on
the back of multi-function telephone Art. 3562. Con-
nect the other end of the cord to the telephone line
from the telephone switchboard (Art. 3528/N-3528)
by inserting the plug in the socket on accessory Art.
3560 (detail A).
Fig. 11 Attach the telephone to the mounting bracket by
hanging it over the hooks and pushing it down
until it is locked in place. Insert monitor cable in
the connector marked "CN1" on the connecting
circuit board (detail B). Finally mount the monitor
by hanging it over the hooks and pushing it down
until it is locked in place. To detach the telephone or
monitor from the mounting bracket, prise open the
safety tab with a screwdriver and detach the unit
by pushing it up (in the opposite direction to that
indicated by arrows 1 and 2).
N.B.:
Do not use the cable supplied with the connecting
circuit board.
Installation rules
Installation should be carried out by qualified personnel in compliance with
the current regulations regarding the installation of electrical equipment
in the country where the products are installed.
Conformity
EMC directive
Standards EN 61000-6-1 and EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may
contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or
packaging, this means the product must not be included with
other general waste at the end of its working life. The user
must take the worn product to a sorted waste center, or return
it to the retailer when purchasing a new one. Products for disposal can
be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400m
than 25cm. An efficient sorted waste collection for the environmentally
friendly disposal of the used device, or its subsequent recycling, helps
avoid the potential negative effects on the environment and people's
health, and encourages the re-use and/or recycling of the construction
materials.
EN
, if they measure less
2
3