3
WIRING
Risk of burn. Allow light engine/fixture to cool before
handling.
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements inclusive of grounding.
NOTE: Verify that supply voltage is correct by
comparing it to nameplate BEFORE applying power.
• The fixture connections will accept service leads
ranging in size from AWG No. 16 through No. 12.
• Connect fixture black lead to supply L1. Connect
fixture white lead to supply N/L2. Connect fixture
yellow/green grounding lead to supply G.
• For non-motion sensor version, the dimming leads
are Violet (DIM+) and Gray(DIM-)
JUNCTION
BOX
LINE
GREEN
NUETRAL
VIOLET
GREY
CAUTION
SUPPLY WIRING
LUMINAIRE
LINE-BlACK
GROUND-GREEN
NUETRAL-WHITE
DIM(+)VIOLET
DIM(+)GREY
4
MAINTENANCE/CLEANING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
• To maintain high efficiency, occasional cleaning of
the lens outer surface may be needed, with frequency
dependent on local conditions.
• Use a nonabrasive mild soap or detergent of neutral
pH (pH approximately 6 to 8) which contains no
chlorinated or aromatic hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
5
STORAGE
• Prior to installation, units should NOT be stored
unprotected outside in corrugated (cardboard) boxes.
• Until installation, all units should be in a roofed dry
storage area or protected with a waterproof tarp in
such a way as to keep water off the corrugated
(cardboard) boxes.
• The storage area should not exceed -40°C (-40°F)
to 50°C (122°F).