Maintenance / Cleaning - GE current GEH-6069 Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3a. Tether Attachment
• Verify service leads meet nameplate temperature rating.
• Install tether (if required) with #10 screws included in
fixture package to hole on back of the housing as
shown in figure 5. The other end of tether is connected
to center threaded stud on backplate using hex nut
provided (Figure 6).
3b. Service Leads
• Route service leads through conduit & hub to the
fixture junction box as in figures 7 and 8.
• Units are provided with leads exiting the fixture for
connection with service leads and (if ordered) wired
dimming.
• Connect power to luminaire where Black is Line, White
is Neutral and Green is Ground.
Figure 6
3c. Wired Dimming
• Connect wired dimming leads per Table 1
• Customer supplied dimming leads 600 volt min.
TABLE 1. Wired Dimming Control Connections
0 VDC (-)
Up to 10 VDC (+)
3d. Install fixture to backplate
• Route tether in drain hole slot when closing fixture to
backplate as shown in figure 5.
• Mount fixture to backplate using the threaded studs
on the backplate and the provided hex nuts as shown
in figure 8.
• Tighten hex nuts to 30 in-lbs.
Figure 7
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation,
operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the
matter should be referred to Current, powered by GE.
All trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory
conditions. Current, powered by GE is a business of the General Electric Company.
© 2018 GE.
www.currentbyge.com
Gray Lead
Violet Lead
GEH6069 (Rev 10/02/18)
Figure 8
4
MAINTENANCE/CLEANING
WARNING
Risk of electrical shock. Make certain power is off before
attempting any maintenance of the product.
• Occasional cleaning of the outer lens surface may be
needed.
• Use a mild, non-abrasive soap or detergent, of neutral
pH (pH approximately 6 to 8), containing no chlorinated
or aromatic hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
5
STORAGE
• Packaged units should NOT be stored unprotected
outdoors in corrugated (cardboard) boxes.
• Store packaged units in a covered dry area not
exceeding -40°C (-40°F) to 50°C (122°F) such as a
roofed area or covered with a secured tarp to keep
water off the corrugated (cardboard) packaging.
NOTES:
• Make sure all electrical power is turned off while
installing the fixture.
• If the service leads are damaged, it must be replaced
by the manufacturer or its service agent or a similar
qualified person in order to avoid a hazard.
• The canopy deck needs to be able to support a load of
20 pounds or more to avoid fixture falling.

Publicidad