14. TROUBLESHOOTING

- CAUTION!!! All maintenance operations must be performed
exclusively with the machine switched off, with the selector set to
"0" and the power plug disconnected from the mains.
Trouble
Causes
Current does not reach
the supply line
The socket and plug
are not connected
properly
The differential switch
is off
The motor does not
The power cable from
start when the start
the plug to the panel
switch is pressed
is cut off
An electric wire inside
the motor terminal strip
is cut off
An electric wire inside
the panel is cut off
The start switch is
faulty
Low water level in tank Restore the water level
Pump fi lter clogged
Cooling water fails
Current fails to reach
to reach the blade
the pump
Pump failure
Blade fi tted in the
opposite direction to
The blade does
that of rotation
not cut
Worn blade
* Operation to be carried out by an electrician
IMER U.S.A. Inc.
SMART CUT 350 14"
Remedies
Check the line *
Restore correct
connection
Turn the differential
switch on
Change the cable *
Restore the connection *
Change the switch *
Change the switch *
Clean the pump fi lter
Check the pump
electrical supply *
Change the pump *
Remove the blade
and reposition it in the
direction shown on the
blade label
Change the blade
6