Descargar Imprimir esta página

CAME Z Serie Manual Del Usuario página 2

Ocultar thumbs Ver también para Z Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DESCRIPTION
Control panel for 230V gearmotors.
This unit has been designed and built by CAME in accordence with current safety
standards UNI 8612.
Single-channel radio receiver on 433.92MHz.
The rated power supply of the gearmotor must be not exceed 500W. The overall
power of the 24V accessories must be not exceed 5W.
The control panel must be supplied (voltage 230V a.c., Frequency 50÷60Hz) on
terminals L1-L2, protected by a 5A fuse on the power input. The controls operate at a
low voltage (24V) protected by a 630mA fuse; the same low voltage can also used to
supply the photocells, if fitted.
SAFETY FUNCTIONS
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if the photocells identify an obstacle while the
gate is closing, they will reverse the direction of movement until the gate is completely
open;
- Total stop (1-2), shutdown of gate movement without automatic closing; a
pushbutton or radio remote control must be actuated to resume movement.
FUNCTIONS AVAILABLE
- "Human presence" control: the gate is in motion only whilst the command button is
pressed (escludes the radio control);
- Automatic closing: closure begins after a pre-established time span (which can be
set), after the gate's complete aperture; it is nonetheless subject to the use of possible
safety accessories and it is discontinued after a "stop" command has been given or
when power is unavailable;
OTHER ACCESORIES WHICH CAN BE CONNECTED
- Courtesy light (E1-E3): a light that comes on each time the opening command is
activated and which stays on for 130 seconds (i.e. the garage's outdoor light)
ADJUSTMENTS
- Trimmer TL = Operating time: 8" to 75";
- Trimmer TCA = Automatic closing time: 3" to 120".
!
ATTENTION
- To prevent improper operation, do not install receivers at
distances of less than 4-5 m (between one receiver and the
another).
- The receiver must be equipped with an antenna.
- It is good practice to position the antenna as high as
possible from ground level, and as far away as possible from
metallic structures in reinforced cement.
- 2 -
ENGLISH
155
ABS cabinet for outdoor use with
IP54 level of protection,factory-
readied for connection of the
antenna.
165
45
(mm)
30

Publicidad

loading

Este manual también es adecuado para:

Zr23