Rating Data; Operating Conditions; Working Instructions - SUHNER ABRASIVE SHS 700 Documentación Técnica

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Remove the blade housing by drawing it towards.
Detach the blade from the blade housing. To connect
the blade, follow the above instructions in reverse order.
Tighten the screws with max. 1.5 Nm. After connecting,
press the grease cup button two to three times.
Very sharp blade!
2.1.3 Connecting/detaching the thumb rest
Dissolve the tension nut with a socket spanner and pull
them out.
Pull the handle and the ring off from the mount.
Replace the ring with the thumb rest. There are different
possible positions available. Push the handle in the de-
sired position on the carrier. Screw the tension nut with a
socket spanner and tighten them.

2.2 Rating data

Blade
Maximum speed
Vibration
Weight
The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure.
Loosening up your arms and hands at regular intervals
prevents muscle tenseness from adversely affecting your
health.

2.3 Operating conditions

Temperature range during operation: -7 to +50°C
Relative air humidity: 95% at +10°C not condensed
3.
haNDLINg

3.1 Working instructions

Focus on an ergonomic stance and movements when
working with the tool. You should always stretch out the
thumb of the hand holding the hand piece. When work-
ing in sweeps or one continuous pass, keep the surface
of the blade as flat as possible on the surface you are
working. For maximum working efficiency we recommend
keeping replacement blades ready at all times.
During operations the tool must be lubricated reg-
ularly from the grease cup!
For any further questions on efficient working,
please contact the area representative or the manufac-
turer.
Ø 70mm
6000min
-1
≤2.5m/s
2
311g
/ o
PERaTIoN
25

Publicidad

Tabla de contenido
loading

Tabla de contenido