Fisher Controls
Type R312 Second Stage LP-Gas
Regulator
Figure 1. Type R312 Regulator
Failure to follow these instructions or to properly
install and maintain this equipment could result in
an explosion and/or fire causing property damage
and personal injury or death.
Fisher equipment must be installed, operated, and
maintained in accordance with federal, state, and
local codes and Fisher instructions. The installation
in most states must also comply with NFPA No. 54
and 58 standards.
Only personnel trained in the proper procedures,
codes, standards, and regulations of the LP-gas in-
dustry should install and service this equipment.
THINGS TO TELL THE GAS CUSTOMER:
1. Point out the regulator's vent to the customer (or vent assembly
or vent tube), and stress that this opening must remain
unobstructed at all times. Tell the customer to be sure to check
the vent opening after a freezing rain, sleet storm, or snow to make
sure ice has not formed in the vent.
2. Show the customer the shutoff valve on the container. The
customer should close this valve immediately if gas is smelled,
appliance pilot lights fail to stay on or appear higher than usual, or
any other abnormal situation occurs.
3. Tell the customer to call your company to service the regulator if
the regulator vents gas or a leak develops in the system. Only a
qualified gas serviceman should install or service the regulator.
Regulador para Gas-LP de Segunda
Etapa Tipo R312
Figura 1. Regulador Tipo R312
ADVERTENCIA
El no cumplir con estas instrucciones o no instalar
y dar mantenimiento apropiado a este equipo
puede resultar en explosión y/o incendio, resultando
en daños, heridas o la muerte.
Los reguladores Fisher deben instalarse, operarse
y recibir mantenimiento de acuerdo con las
regulaciones, leyes y códigos federales, estatales y
municipales, e instrucciones de Fisher. En la
mayoría de los estados, la instalación debe cumplir,
también, con los estándares NFPA 54 y 58.
Sólo personal entrenado en los procedimientos,
códigos, estándares y regulaciones apropiadas para
la industria de gas LP debe instalar y dar servicio a
este equipo.
QUE DEBE INFORMARLE AL USUARIO:
1. Muestre al cliente la ventila del regulador (el ensamble de la ventila
o la tubería de la ventila), y haga énfasis en que esta abertura debe
estar siempre libre de obstrucciones. Indique al cliente que es
necesario que chequee la ventila después de una nevada, granizada
o tormenta de agua congelada, para asegurarse de que no se formó
hielo en la ventila.
2. Muestre al cliente el contenedor de la válvula para apagar el
regulador y adviértale que debe cerrarla de inmediato, en caso de
oler a gas, que exista falla en el encendido de los pilotos o se vean de
mayor tamaño que el normal, o si ocurre cualquier situación anormal.
3. Indique al cliente que es necesario solicitar a la compañía una
visita de servicio si el regulador esta venteando gas o si existen
fugas en el sistema. Sólo una persona calificada debe instalar o
dar servicio al regulador.
R312
MCK-1199
08/99
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Fisher R312

  • Página 1 Fisher equipment must be installed, operated, and Los reguladores Fisher deben instalarse, operarse maintained in accordance with federal, state, and y recibir mantenimiento de acuerdo con las local codes and Fisher instructions.
  • Página 2: Instalación

    This instruction manual covers installation and maintenance for the Este manual de instrucciones cubre la instalación y mantenimiento del regulador de segunda etapa Tipo R312. Los reguladores R312 Type R312 second stage regulator. The Type R312 has an internal disponen de una válvula de alivio interna. relief valve.
  • Página 3 Fisher P212 Vent Kit. The same installation precautions apply to the P212 screened end as to the regulator vent covered previously. To Si la instalación de un R312 requiere una linea de venteo, use un kit install the P212 remove the regulator vent screen and install the P212 de Fisher.
  • Página 4: Overpressure Protection

    R312 Fisher Controls a todo tiempo. Para mayor información sobre instalaciones Suggested Installation, Inspection,” available from The National subterráneas, pida una copia de “Instalación e Inspección de Propane Gas Association, 1600 Eisenhower Lane, Suite 100, Lisle, Sistemas de Gas Subterráneos”, disponible en The National Pro-...
  • Página 5: Mantenimiento

    R312 Fisher Controls El regulador R312 cuenta con una válvula de alivio interna que se The R312 regulator has an internal relief valve that opens when abre cuando la presión de salida alcanza aproximadamente 1 psig downstream pressure reaches approximately 1 psig on regulators (69 milibares) en reguladores ajustados a 11 pulgadas ca (27.4...
  • Página 6: Filtro De Entrada

    Fisher Controls se reserva el derecho de alterar implied, regarding the products or services herein or their use or applicability. Fisher Controls reserves the o mejorar los diseños o especificaciones de los equipos aqui descritos sin previo aviso.

Tabla de contenido