Installation And Lubrication; Parts And Maintenance - Ingersoll Rand 88V Serie Especificaciones Del Producto

Ocultar thumbs Ver también para 88V Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Lubrication

Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain condensate from
valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a properly sized Safety Air Fuse
upstream of hose and use an anti-whip device across any hose coupling without internal shut-off, to prevent
hose whipping if a hose fails or coupling disconnects. See drawing 16573198 and table on page 2.
Maintenance frequency is shown in circular arrow and defined as h=hours, d=days, and m=months. Items
identified as:
1.
Air filter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve

Parts and Maintenance

When the life of the tool has expired, it is recommended that the tool be disassembled, degreased and parts
be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll-Rand Office or Distributor.
4
5.
Hose diameter
6.
Thread size
7.
Coupling
8.
Safety Air Fuse
9
Hose Whip
10. Oil
11. Oil (Fill Oil Chamber,
if applicable.)
Form 16576092-Edition 1

Publicidad

Tabla de contenido
loading

Tabla de contenido