Installation And Lubrication; Parts And Maintenance - Ingersoll Rand 77A Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
EN

Installation and Lubrication

Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16605834 and table on page 2. Maintenance frequency is shown in a
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter

Parts and Maintenance

When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
Original instructions are in English. Other languages are a translation of the original instructions.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
6.
Thread size
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Grease - through fitting
80221773_ed3

Publicidad

Tabla de contenido
loading

Tabla de contenido