Connecting the fixture to 12 V
The already installed lamp means the fixture is immediately ready for
use. Therefore you do not need to install the lamp first. This fixture can
be built into various sorts of decorative paving, such as concrete or
natural stone, or wooden constructions such as decking, walls, fenc-
es, pond edges etc.
Step 1a (concrete, stone and similar)
Replace a 100 x 100 mm / 3.9 x 3.9 inch stone with this fixture or, in the
case of large, unbroken surfaces, saw out a 100 x 100 mm / 3.9 x 3.9
inch piece. The fixture can then be placed directly on the underlying
sand bed. (Go to step 3.)
Step 1b (wooden structures)
Remove the plastic housing by unscrewing the Torx bolts on the top
of the fixture. Then saw a hole of 60 x 40 mm / 2.4 x 1.6 inches and about
20 mm / 0.8 inches deep (the LED unit fits into this).
Step 2b
Feed the connector for the fixture through the hole and then carefully
insert the fixture into the recess. Attach the fixture with the wood
screws provided. (Fig. 1)
Step 3
Join the Easy-Lock connector to the main cable. (Fig. 2)
a. There are two cable ducts. The duct with the narrowest slot is suit-
able for the 14/2 and 10/2 main cable. When using the old (thick)
10/2 cable, you should use the duct with the wide slot.
b. Clamp the correct cable duct on top of the main cable. There
should be no space left between the cable and the duct.
c. Place the cable duct (with the cable at the bottom) in the Easy-
Lock connector.
d. Tighten the threaded cap on the Easy-Lock connector. This will
cause the contacts to be pushed through the insulation on the ca-
ble. In tightening the cap, a little gel is applied to the contacts in the
Easy-Lock connector. This serves to protect the contacts against
moisture. A little gel may possibly come out of the Easy-Lock con-
nector: so after installation (and/or before a meal), wash your
hands with soap and water, and avoid the gel coming into contact
with your eyes.
Step 4
Connect the power cable to the fixture by connecting the mini-
connector. (Fig. 3)
If the lamp does not work correctly, check that the Easy-Lock connec-
tor is properly connected to the main cable. Do the same for the mini-
connector. Repeat steps 3 and 4. When the fixture is connected to the
main cable also check that the contacts of the Easy-Lock connector
are not bent. If you have any problems, contact your dealer.
General maintenance advice
We advise wiping the fixture down at least once a year using a clean