TESY Compact 30 Instrucciones De Uso Y Mantenimiento página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
2.
Water heater connection to the water supply system
EN
Fig.4a - installation scheme above sink
Fig.4b - installation scheme under sink
Where: 1 – input pipe, 2 – safety valve (0.8 MPa), 3 –
reduction valve (if the water supply pressure exceeds
0,6 MPa), 4 – stop valve, 5 – bell-mouth discharge to the
sewer, 6 – hose; 7 - Drain water tap.
Upon connecting the water heater to the water supply
system, take care of the indicative color markings /rings/
of the pipes:
BLUE - for cold /in-flowing/ water,
RED - for hot /out-flowig/ water.
The mounting of the safety return-valve supplied with the
water heater is obligatory. The safety return-valve must
be installed on the cold water supply pipe, according to
the arrow stamped on its body that indicates the supplied
water direction.
Exception: If the local regulations (norms) require the
usage of another protection valve or mechanism (in
accordance with EN 1487 or EN 1489), then it must be bought
additionally. For mechanisms operating in accordance with
EN 1487 the announced operational pressure must be no
more than 0.7 MPa. For other protection valves, the pressure
at which they are calibrated must be 0.1 MPa lower than the
one marked on the appliance's sign. In these cases the safety
valve which the appliance is supplied with should not be
used.
ATTENTION! Other type of stopping armature is not
allowed between the protection return valve (the
protective device) and the appliance.
ATTENTION! Any other /old/ safety return-valves may
lead to a failure of your appliance, therefore they
must be removed.
ATTENTION! Fixing the safety return-valve to threads
longer than 10 mm is not allowed, as it could
damaged the valve and could make the use of your
appliance dangerous.
ATTENTION! The safety valve and the pipe between the
valve and the water heater must be protected from
freezing. During hose draining - its free end must be always
open to the atmosphere (not to be immersed). Make sure that
the hose is also protected from freezing.
The electric water heater is filled with water by opening
the tap on the cold water supply system and the tap on
the hot water mixing faucet. After the filling process is
complete, a constant stream of water should flow from the
water-mixing faucet. Now you can shut the hot water tap
on the mixing faucet.
When you must empty the water heater, you should first
cut it off the power supply.
10
Instructions for use and maintenance
appliances
Draining procedure for
installed ABOVE SINKS:
1.
First shut the cold water supply valve
2.
Open the hot water valve on the mixing-faucet
3.
The water tap 7 (fig 4a) must be opened to drain the
water from water tank. If there is no such tap build in the
pipe line, than the water can be drain directly from inlet
pipe of water tank after when you disconnect it from
water main
IMPORTANT: When draining the
measures to prevent damages caused by the flowing
water.
appliances
Draining procedure for
installed UNDER SINKS:
appliance
1.
Switch the
2.
Dismantle the connecting water fittings from the
appliance
.
appliance
3.
Disassemble the
turn it so the pipes point to the floor and pour the water
in a vessel you have prepared for the purpose. Wait until
all the water drains out of the
In case that the pressure in the water mains is over the
value pointed out in the above paragraph I, then it is
necessary to assemble a pressure reduce valve, otherwise
the water heater would not function properly. The
Manufacturer does not assume any liability for problems
arising out of the appliance's improper use.
3.
Water heater's electrical connection (fig.3)
ATTENTION! Before you switch the power supply,
make sure the appliance is full of water.
3.1.
Models fit with power supply cord combined with a
plug
Swich on the plug to the correctly connected and
earthed socket
The socket must be connected to the electrical
network through a separate circuit, protected with fuse
16 A.
The electrical technician must check if the previous
requirements are fulfilled
The appliance should be positioned so that the switched
on plug to be easy accessible.
The water heater can be disconnected from the power
supply by unplugging.
Explanations to Fig.5:
T1 – thermal regulator, T2 – thermal circuit breaker, IL1, IL2
– light indicator, R – heater.
designed to be
appliance
, take
designed to be
off the power supply network.
from its installation place,
appliance
.