V.
OPERATING THE DEVICE
Включване на уреда
1.
Before initial start of the device, please make sure that the
water heater has been correctly connected to the electrical
network and that it is filled up with water.
Clarification to Fig.2:
1 - Light indicators;
2 - Regulator knob – for temperature setting.
2.
Light indicators
The appliance has two indicating lamps (fig.2).
•
The indicator IL1 light in green color - when the appliance
is connected to the power supply and indicates that voltage is
supplied to it.
•
The indicator IL2 light in red color when the
switched on in water heating mode.
•
The indicator IL2 light in yellow color - when the water
reaches the preset temperature and indicates that the
appliance is not in operation.
3.
Temperature setup
This setup allows the gradual setting of the desired
temperature, achieved by using a handle on the control
panel. Turn the knob to the upward indication, in order to
increase the temperature of the hot water.
The "min" position on the knob does not protect the
appliance from freezing.
If the temperature in the room is likely to fall below
0° C, the appliance must be disconnected from the electrical
installation and drained.
WARNING! Once a month set the knob to the
position 'maximum temperature' for a period of 24
hours (unless the device is constantly operated in this mode).
Thus you will ensure better hygiene of the heated water.
Protection according to the temperature (valid for
4.
all models).
The appliance is equipped with a special facility (thermal
circuit-breaker) for protection against over-heating of the
water, which is switching off the heater from the electricity
network, when the temperature reaches too high values.
When this device operates, it does not self-reset and the
appliance will not work. Please call an authorized
service for solving the problem.
RUST PROTECTION MAGNESIUM ANODE
VI.
The magnesium anode protects the water tank's inner
surface from corrosion. The anode element is an element
undergoing wear and tear and is subject to periodic
replacement. This is cost for the user.
In view of the long-term and accident free use of your water
heater, the manufacturer recommends periodic inspections
of the magnesium anode's condition by a qualified
technician and replacement whenever required, and this
could be performed during the appliance's technical
preventive maintenance.
For replacements, please contact the authorized service
stations!
English
VII.
PERIODIC MAINTENANCE
Under normal use of the heater, under the influence of high
temperature, lime scale /the so-called lime scale layer/ is
deposited upon the heating element's surface. This worsens
the heat exchange between the heating element and water.
The heating element's surface temperature increases along
/of boiling water/. The thermoregulator begins to switch
on and off more frequently. A ''deceptive" activation of
the thermal protection is possible. Due to these facts, the
manufacturer recommends preventive maintenance of
your water heater every two years by an authorized service
center or service base. This protective maintenance must
include cleaning and inspection of the anode protector (for
water heaters with glass-ceramic coating), which shall be
replace with a new one if need arises.
appliance
is
In order to clean the appliances use a damp cloth. Do not
clean with abrasive or solvent content detergents. Do not
pour water over the appliance.
The manufacturer does not bare the responsibility
for all consequences caused by not obeying the
instructions, given hereby.
the stations organized for the purpose (if available).
Environmental protection instructions.
Old electric appliances contain prescious
materials and must not be disposed with
the domestic waste! Please make your
active contribution to the protection of the
environment and dispose of the appliance in
Instructions for use and maintenance
EN
11