Install The Electrical Outlet - Kohler Sterling 7613 Serie Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3-1/2"
42-1/2"
(8.9 cm)
(108 cm)
Install a GFCI-protected 120
V, 15 A grounded outlet.
1-1/2" (3.8 cm) minimum from the floor.

7. Install the Electrical Outlet

CAUTION: Risk of personal injury. Do not turn on the power until instructed to do so.
NOTE: The whirlpool is equipped with a cord and plug. All pump and control wiring has been completed
at the factory.
NOTE: Refer to the label near the pump. This label identifies the electrical rating and model number of the
whirlpool.
Install the GFCI-protected, 120 V, 15 A grounded outlet inside the access panel within 24" (61 cm) of
the pump's future location. The electrical box must be located a minimum of 1-1/2" (3.8 cm) above
the subfloor.
Install a bonding (grounding) conductor at the future location of the pump in accordance with any
applicable local codes.
Sterling
Block Location
5" (12.7 cm)
Bond in accordance
with applicable codes.
54-5/8"
(138.7 cm)
13
1072813-2-A