Fill with water at least 2" (5.1 cm)
above the highest jet.
Turn the jet trim ring
clockwise to
decrease the flow.
Turn the jet trim ring counterclockwise
to increase the flow.
13. Confirm Proper Operation
Please read these steps carefully before you operate your whirlpool.
Verify all electrical connections.
Verify that the pump banding straps have been cut.
Close the circuit breaker for the whirlpool pump.
Fill the Whirlpool
Fill the whirlpool to at least 2" (5.1 cm) above the top of the highest jet.

Operating Sequence

NOTE: If you encounter problems with the operating sequence, refer to the "Troubleshooting Table"
section in this manual and in the Homeowners Guide. The Homeowners Guide also includes warranty
information.
Press the air actuator to turn on the whirlpool jets.
Verify that the pump starts and operates without excessive noise or vibration.
Verify that water is circulating and flowing from each jet.
Adjust each large jet for optimum flow. Turn the trim ring clockwise to decrease the flow, and
counterclockwise to increase the flow.
After 5 minutes, check the piping connections for leaks. Repair any leaks.
Press the air actuator a second time to turn off the whirlpool.
Verify that the pump stops.
Drain the whirlpool.
Sterling
Position the jet
nozzles to direct
the water flow as
desired.
17
Press the air switch to turn the
whirlpool on or off.
1072813-2-A