72" (182.9 cm)
44"
(111.8 cm)
60"
(152.4 cm)
20-1/2"
20"
(52.1 cm)
(50.8 cm)

Roughing-In

IMPORTANT! All dimensions are nominal. The stud opening tolerance is +1/8" (3 mm)/-0. Carefully
measure your fixture before determining enclosure size. Some shimming between the stud frame and the
fixture may be required. If a firewall is required, roughing-in dimensions will have to increase according to
the thickness of the firewall material. Stud opening dimensions must be measured toward the exposed
side of the wall material. Dimensions given in the roughing-in information are crucial for proper
installation. Construct the framing and plumbing accurately.

1. New Framing Construction

NOTE: Refer to the "Roughing-In" section for dimensions.
WARNING: Risk of product and property damage. The whirlpool must be supported by the
subfloor.
Framing Provisions
A subfloor must be installed. The whirlpool must be positioned to allow clearance for drainage
through the floor joists or slab and to allow convenient plumbing installation.
IMPORTANT! Accessories that require backing or support are not recommended for this installation.
Installing these accessories could void the warranty.
If installing this unit with a shower door, refer to the shower door manufacturer's instructions for
any special framing considerations. It may be appropriate to add studs for pivot shower door
support.
IMPORTANT! Construct the floor of plywood. If whirlpool is installed over material other than plywood,
friction may cause squeaking over time.
1072813-2-A
60" (152.4 cm)
44" (111.8 cm)
10-1/4"
(26 cm)
42-7/16" (107.8 cm)
42-7/16"
(107.8 cm)
4-1/4"
(10.8 cm)
24-7/8"
(63.2 cm)
17-1/2" (44.5 cm)
from the Floor to
the Overflow
1" (2.5 cm) from the
Floor to the Drain
6
Recommended faucet area
1/2"
(1.3 cm)
Tile Flange
Detail