Installation Requirements; Tools And Parts; Location Requirements; Important - Whirlpool 3HWED5205SQ0 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed
Flat-blade screwdriver
Phillips screwdriver
Adjustable wrench that opens to 1" (2.5 cm) or hex-head
socket wrench
Level
1/4" socket wrench or 1/4" nut driver
Utility knife
Vent clamps
Pipe-joint compound resistant to LP gas
Sealing gun and compound (for installing new exhaust vent)
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
4 leveling legs

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances.
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
"Recessed Area and Closet Installation Instructions" for
minimum spacing requirements.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.

INSTALLATION REQUIREMENTS

Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. For
recessed area and closet installations, minimum clearances can
be found on the serial tag on the dryer.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease of
installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors with equivalent
air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation Clearances
18"
(45.7 cm)*
0" (0 cm)
Recessed front view
Additional clearances for wall, door and floor moldings may be required or if
external exhaust elbow is used.
48 in
2
.
(310 cm
2
)*
Front
View
24 in
2
(155 cm
2
)*
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
14"
(35.6 cm)
max.
Closet
door
4"
(10.2 cm)
0" (0 cm)
1" (2.5 cm)
Closet side view
3" (7.6 cm)
closet
door
3" (7.6 cm)
3

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido