KDP6
Wall presence detector
•
Rotating sensor head to change
the detection direction (See FIG
13-A, FIG 13-B, FIG 15-A, FIG
15-B)
•
Adjust METER knob to change
detection range.
•
Adjust TIME knob to change the
delay time for light.
•
Refer to section "4.3"to use
the lens mask for minimize the
detection zone.
•
Repeat step 4.2.5 - 4.2.6 until
meets users demands.
•
Be aware of the walk direction
(See FIG 4)
Usage of lens shield
•
KDP6 has three pieces of lens
shield. Lens shield consists of
three layers A/B/C, each layer is
divided into 3 small units a/b/c,
and the unit can mask an angle
of approx. 30º, when mounting
the detector at the height of
2.5M, the outer coverage is:
Layer C. eliminated: mask the
zone with a sector about from
0.5M to 4.5M Layer B eliminated:
mask the zone with a sector
about from 0.5M to 7M. Layer
A eliminated: mask the zone
with a sector about from 0.5M
to 10M. The inner coverage is a
circular with radius of 0.5M (See
FIG 21), separate lens shield can
be eliminated to fit users desired
detection area (See FIG 19 & FIG
Instructions manual |
38
20 & FIG 21).
•
Cut the excess lens shield by a
plier.
•
Fix lens shield: Push the lens
shield into the slot path (See FIG
22). then along the slot path to
turn right or left (See FIG 23).
www.grupotemper.com