Erreka VIVO-D203 Guía Rápida De Instalación Y Programación página 14

Ocultar thumbs Ver también para VIVO-D203:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The
opening
stopper
must
before programming the travel
(see the operator manual).
8
Start opening of leaf 1
with ST1:
8a
With up-and-over door
and slowdown, press
ST1 again to pass from
slow to quick speed.
11
Start opening of leaf 2
with ST1:
14
Start closing of leaf 2
with ST1:
17
Start closing of leaf 1
with ST1:
17a
With up-and-over door
and slowdown, press
ST1 again to pass from
slow to quick speed.
20
U255O
14
Travel programming (all cases)
and
closing
When using operators without encoder or limit switches, adjust the
be
installed
maximum thrust (A6) at the minimum value necessary to move the gate
before programming the run. Failure to do so will mean the
controlboard cannot detect any halting of the gate during the Reset (r5).
The door/gate carries
6
o u t t h e a p p r o a c h
manoeuvre (closes in
order to save the closing
point).
9
Start slowdown of leaf 1
with ST1
( o n l y w i t h C A 0 1 o r
CA02):
U255G
12
Start slowdown of leaf 2
with ST1
(only with CA01 or CA02):
U141K
15
Start slowdown of leaf 2
with ST1
(only with CA01 or CA03):
U141N
18
Start slowdown of leaf 1
with ST1
( o n l y w i t h C A 0 1 o r
CA03):
U255T
21
10
Finish opening of leaf 1 with ST1:
In any case, this is carried
out automatically when
the
opening
(with C700, C701, C703
or C704) or the FCA
(with C702 or C704) is
reached.
U141I
13
Finish opening of leaf 2 with ST1:
In any case, this is carried
out automatically when
the
opening
(with C700, C701, C703
or C704) or the FCA
(with C702 or C704) is
U141L
reached.
16
Finish closing of leaf 2 with ST1:
In any case, this is carried
out automatically when
the closing stopper (with
C700, C701, C703 or
C704) or the FCC (with
C702
or
reached.
U241R
19
Finish closing of leaf 1 with ST1:
In any case, this is carried
out automatically when
the closing stopper (with
C700, C701, C703 or
C704) or the FCC (with
C702
or
reached.
U241U
The anti-trapping safety system continues to run during the
programming operations.
Pedestrian opening is programmed using F3, meaning the travel for
this pedestrian opening does not need to be programmed.
If an obstacle is detected during programming in up-and-over
operation with C5 Closing photocell activated, this will be
considered the point from which the photocell shadow
function should be activated. This only works with Collective
Opening (A901).
U141P
The procedure with a
swing
gate
below.
Proceed
in
manner for sliding gates
or up-and-over doors.
stopper
stopper
C704)
is
C704)
is
is
shown
the
same
U241J
U241M
U241S
U241V