DI-000-06376-20B
Leviton Residential Powerline Carrier Components are designed to provide the greatest signal integrity and noise immunity possible. However, in some
environments intense electrical noise can cause interference with the signal. Leviton has developed hardware and techniques for overcoming this interference
when properly applied.
It is the responsibility of the specifier/installer to test for signal strength and the presence of noise using Leviton test equipment, Cat. Nos. 6385 (Signal Test
Transmitter) and 6386 (Signal Strength Indicator), and to properly apply signal coupling and noise reduction equipment according to the guidelines provided in
the Decora Home Controls (DHC) Technical Manual and the DHC Troubleshooting Guide.
Leviton specifically denies any warranty of performance, stated or implied, where electrical noise interference exists at the time of installation, or subsequent to
installation by the addition of noise-producing devices or equipment, or where these components have been installed for nonresidential applications.
Dimming Module
DHC Components are for residential use only. Installation for any other application voids any warranty, stated or implied.
Rated: 300W, 120VAC, 60Hz
Cat. No. 6376
The Leviton Dimming Module, Cat. No. 6376, is designed for use with DHC Residential Powerline Carrier Components. Cat. No. 6376 functions as a remote
electrical load switching device which responds to commands from one or more controllers remotely located from the module. The module may be set to any of
Incandescent
256 address codes selected at the time of installation. It is mounted at the incandescent fixture it is to control. The module is equipped with leads for easy
installation and attaches firmly to the fixture by means of an adhesive strip. In addition to switching, it provides full range dimming and responds to ALL LIGHTS
INSTALLATION INSTRUCTIONS
ON commands.
Module gradateur
DHC devices will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps
(HID lighting). This includes mercury-vapor, sodium-vapor and metal halide lamps.
Valeurs nominales : 300 W, 120 V c.a., 60 Hz
N
o
de cat. 6376
Minimum Voltage: 112 VAC
Pour charges à incandescence
Maximum Voltage: 138 VAC
DIRECTIVES DE'INSTALLATION
Maximum Number of Modules per Circuit: 10
Input Signal: 121 kHz carrier signal superimposed on AC power line
Minimum Signal Strength: 100 mV
Ambient Operating Temperature: Min. 0˚F (-18˚C) to Max. 104˚F (40˚C)
Módulo Atenuador
Ambient Humidity: 0 to 90% RH non-condensing
Capacidad: 300W, 120VCA, 60Hz
No. de Cat. 6376
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING:
Incandescente
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING:
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A
INSTRUCCIONES DE INSTALACION
RECEPTACLE, MOTOR-OPERATED APPLIANCE, FLUORESCENT LIGHTING FIXTURE, OR A TRANSFORMER-SUPPLIED APPLIANCE.
OTHER CAUTIONS:
1. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING BULBS.
2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL.
3. SAVE THIS INSTRUCTION SHEET. IT CONTAINS IMPORTANT TECHNICAL DATA ALONG WITH TESTING AND TROUBLESHOOTING INFORMATION
WHICH WILL BE USEFUL AFTER INSTALLATION IS COMPLETE.
OTHER NOTES:
1. IF THIS DEVICE WILL BE INSTALLED IN A STAND-ALONE JUNCTION BOX, THE BOX MUST MEASURE AT LEAST 4" X 4" X 1.5", AND THE DEVICE
SHOULD BE MOUNTED BY MEANS OF ADHESIVE STRIPS.
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
2. FOR RETROFIT INSTALLATION, IT IS RECOMMENDED THAT THE EXISTING SWITCH REMAIN IN THE CIRCUIT FOR ADDITIONAL POSITIVE SHUT-
OFF MEANS.
Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of
3. THIS DEVICE MAY BE INSTALLED IN THE JUNCTION BOX SUPPLIED WITH SOME "HIGH-HAT" FIXTURES, PROVIDED THAT THE BOX IS IN THE
its sale by Leviton is free of defects in materials and
PROPER SIZE.
workmanship under normal and proper use for two years from
4. SUPPLY CONDUCTORS MUST BE RATED 40°C (140°F) OR MORE. THE MAXIMUM AMBIENT OPERATING TEMPERATURE AT THE BOX SHOULD NOT
the purchase date. Leviton's only obligation is to correct such
EXCEED 40°C (140°F) FOR THIS DEVICE.
defects by repair or replacement, at its option, if within such
two year period the product is returned prepaid, with proof of
5. ONLY FOR USE WHERE 40° FIXTURE WIRING IS PERMITTED.
purchase date, and a description of the problem to Leviton
TO INSTALL:
Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
1.
WARNING:
York 11362-2591. This warranty excludes and there is
2. Set the Letter and Number Code dials to the desired system address for the fixture to be controlled (see Figure 1).
disclaimed liability for labor for removal of this product or
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
4. Connect lead wires per WIRING DIAGRAM as follows: Twist strands of each lead tightly and, with circuit conductors, push firmly into appropriate wire
misused, opened, abused, or altered in any manner, or is not
connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape.
used under normal operating conditions or not in accordance
5. Mount module in junction box with module code dials facing out.
with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness
6. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
for a particular purpose, but if any implied warranty is required
by the applicable jurisdiction, the duration of any such implied
warranty, including merchantability and fitness for a particular
With Cat. No. 6376 properly wired and powered use the Table Top Controller, Cat. No. 6320, or any other controller, to check for proper module operation as follows:
purpose, is limited to two years. Leviton is not liable for
incidental, indirect, special, or consequential damages,
1. Transmit an ON command to the module. The assigned load should turn ON.
including without limitation, damage to, or loss of use of, any
2. Transmit an OFF command to the module. The assigned load should turn OFF.
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are the
3. Transmit an ALL LIGHTS ON command to the module. The assigned load should turn ON.
exclusive remedies under this warranty, whether based on
4. Transmit an ALL OFF command to the module. The assigned load should turn OFF.
contract, tort or otherwise.
5. Transmit an ON command followed by a DIM command to the module. The assigned load should turn ON, then dim. Once the load is dimmed, restore it to
full brightness by transmitting a BRIGHT command followed by an ALL LIGHTS ON command to the module. The assigned load should attain full brightness.
For Technical Assistance Call:
6. When Cat. No. 6376 is observed to switch its assigned load properly in response to command signals, it is cleared for normal use.
1-800-824-3005 (U.S.A. Only)
www.leviton.com
If Cat. No. 6376 is not functioning improperly, proceed with the following steps:
1. Confirm that the module is wired exactly as shown in the WIRING DIAGRAM.
2. Confirm that the module is being supplied from a 120V, 60Hz AC source ONLY.
3. Confirm that the load being controlled does not exceed the 300W module rating, including at start-up.
4. Confirm that the load being powered is in proper working order (check for burned out bulbs, etc.)
5. Confirm that the module is being used with an incandescent load only.
6. Confirm that the module's Letter and Number codes are correctly set
NOTE: If the module still does not operate properly after checking items 1-6, the fault does not lie with the module. Proceed with steps 7 and 9.
7. Confirm that the controller is powered and set to transmit to the same Letter and Unit codes set on the module.
8. Set the controller to transmit address P1. Using a Cat No. 6386 Signal Strength Indicator plugged in on the same branch circuit location as the controller,
confirm that the controller is transmitting a minimum reading of 2 volts of command signal at the HI-RANGE setting. If the signal strength is less than 2 volts,
DI-000-06376-20B
have the controller checked.
DI-000-06376-20B
1
ENGLISH
INTRODUCTION
DESCRIPTION
APPLICATIONS
SPECIFICATIONS
INSTALLATION INSTRUCTIONS
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
TESTING PROCEDURE
PERFECT PERFORMANCE CHECKLIST
9. Check for the adequate command signal strength at the Cat. No. 6376 location as follows:
A. Plug the Cat. No. 6385 Signal Test Transmitter into a receptacle on the same circuit as the controller.
B. Using the Cat. No. 6386 Signal Strength Indicator at the Cat. No. 6376 location, check the command signal amplitude. Signal strength must be 100mV
minimum. If there is less than 100mV of signal present, it may be necessary to couple both legs of the 120/240 volt power service at the entrance panel
using Cat. No. 6299 Signal Bridge.
C. If the YELLOW ERROR CONDITION indicator is lit, there is electrical "noise" present on the AC line which is interfering with proper module operation.
The source of the noise must be identified and either filtered out or eliminated (see DHC Technical Manual).
FRANÇAIS
INTRODUCTION
Les composantes résidentielles à courant porteur de Leviton sont conçues pour assurer la meilleure intégrité possible et offrir une immunité supérieure au bruit,
il existe cependant des applications particulièrement «bruyantes» où des interférences électriques intenses risquent de nuire aux signaux; Leviton a conçu les
dispositifs et élaboré les techniques qui, appliqués adéquatement, permettent de remédier à ce problème.
Il revient toutefois à l'installateur (ou au rédacteur de devis) de vérifier l'intensité du signal et la présence d'interférences au moyen des appareils de vérification de
Leviton, comme l'émetteur de signal de vérification et l'indicateur d'intensité du signal (n
couplage et de réduction du bruit nécessaire, conformément aux procédures décrites dans le manuel sur les commandes domotiques Decora
guide de diagnostic des anomalies.
Leviton n'offre aucune garantie de rendement, explicite ou implicite, en présence d'interférences dues au bruit électrique au moment de l'installation, ou
ultérieurement en raison de l'ajout de dispositifs ou d'appareils en produisant, ou encore, si ce dispositif est installé dans une application autre que résidentielle.
Les CDD sont conçues pour les applications résidentielles seulement; toute autre installation pourrait en annuler la garantie, implicite ou explicite.
DESCRIPTION
Le module gradateur, N° de cat. 6376, est conçu pour être utilisé avec les composantes résidentielles à courant porteur (CDD); le module gradateur de Leviton,
N° de cat. 6376, permute les charges électriques auxquelles il est raccordé en réponse aux commandes d'un ou de plusieurs contrôleurs installés à distance;
le module peut commander jusqu'à 256 codes d'adresse choisis au moment de l'installation; il est facile à installer grâce à ses fils de sortie intégrés; il suffit de
le fixer au liminaire au moyen de la lisière de ruban adhésif comprise; en plus d'effectuer la commutation et la gradation pleine bande de ses charges, le
module répond aussi à la commande TOUTES LUMIÈRES ALLUMÉES.
APPLICATIONS
Les dispositifs CDD ne conviennent pas aux charges d'éclairage alimentées par des transformateurs haute fréquence ou électroniques à basse tension, ni aux
lampes à décharge à haute intensité, et compris les lampes à vapeur de mercure ou de sodium et celles aux halogénures.
FICHE TECHNIQUE
Tension minimale : 112V c.a.
Tension maximale : 138V c.a.
Nombre maximal de modules sur un circuit : 10
Signal d'entrée : signal porteur de 121 kHz superposé sur une ligne d'alimentation électrique c.a.
Intensité minimale du signal : 100mV
Température ambiante de fonctionnement : -18 ˚C minimum, 40 ˚C maximum
Humidité ambiante : hum. rel. 0 à 90 %, sans condensation
DIRECTIVES D'INSTALLATION
AVERTISSEMENT :
INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
AVERTISSEMENT :
À DÉFAUT DE BIEN COMPRENDRE LES PRÉSENTES DIRECTIVES, EN TOUT OU EN PARTIE, ON DOIT FAIRE APPEL À UN
ÉLECTRICIEN QUALIFIÉ.
AVERTISSEMENT :
AFIN D'ÉVITER LA SURCHAUFFE OU L'ENDOMMAGEMENT ÉVENTUEL DE CE DISPOSITIF ET DES APPAREILS QUI LUI SONT
RACCORDÉS, NE PAS L'INSTALLER POUR COMMANDER UNE PRISE, UN LUMINAIRE FLUORESCENT OU UN APPAREIL MOTORISÉ OU À TRANSFORMATEUR.
MISES EN GARDE COMPLÉMENTAIRES :
1. COUPER LE COURANT AVANT DE PROCÉDER À L'ENTRETIEN DES LUMINAIRES OU AU REMPLACEMENT DES LAMPES.
2. N'UTILISER CE DISPOSITIF QU'AVEC DU FIL DE CUIVRE; EN PRÉSENCE DE FIL D'ALUMINIUM, UTILISER SEULEMENT LES DISPOSITIFS PORTANT
LA MARQUE CO/ALR OU CU/AL.
3. CE FEUILLET DE DIRECTIVES DOIT ÊTRE CONSERVÉ; IL CONTIENT DES RENSEIGNEMENTS TECHNIQUES RELATIFS À LA VÉRIFICATION ET AU
DIAGNOSTIC DES ANOMALIES QUI POURRAIENT S'AVÉRER UTILES APRÈS L'INSTALLATION.
REMARQUES COMPLÉMENTAIRES :
1. LE MODULE PEUT ÊTRE INSTALLÉ DANS UNE BOÎTE DE DÉRIVATION AUTONOME MESURANT AU MOINS 10 SUR 10 SUR 3,8 CM AU MOYEN
D'UNE LISIÈRE DE RUBAN ADHÉSIF.
2. DANS LE CAS DE RÉFECTIONS, ON RECOMMANDE DE GARDER L'INTERRUPTEUR EXISTANT AFIN D'ASSURER AU CIRCUIT UN MODE DE
SECTIONNEMENT ADDITIONNEL.
3. CE DISPOSITIF PEUT ÊTRE INSTALLÉ DANS LES BOÎTES FOURNIES AVEC LES LUMINAIRES TUBULAIRES, À CONDITION QUE CES BOÎTES
SOIENT DE DIMENSIONS APPROPRIÉES.
4. LA TEMPÉRATURE AMBIANTE À LA BOÎTES NE DOIT PAS ÊTRE SUPÉRIEURE À 40º C (140º F); UTILISER DES FILS D'ALIMENTATION APTES À
SUBIR CETTE TEMPÉRATURE.
5. N'UTILISER CE DISPOSITIF QUE DANS LES APPLICATIONS PERMETTANT L'INSTALLATION DE FILS APTES À SUPPORTER UNE TEMPÉRATURE DE
40º C.
INSTALLATION :
1.
AVERTISSEMENT :
POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU D'ÉLECTROCUTION, COUPER LE COURANT AU
FUSIBLE OU AU DISJONCTEUR ET S'ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L'INSTALLATION.
2. Régler les cadrans alphabétique et numérique pour former l'adresse correspondant à la charge commandée (figure 1).
3. Dénuder chacun des conducteurs de circuit sur environ 1.9 cm (3/4 po); s'assurer que les extrémités soient bien raidies.
4. Raccorder les fils conformément au SCHÉMA DE CÂBLAGE de la façon suivante : torsader solidement ensemble les brins de chaque fil de sortie avec le
conducteur correspondant et enfoncer fermement les raccords dans une marette de grosseur appropriée, en vissant cette dernière et en s'assurant qu'aucun
brin de cuivre ne dépasse; protéger les raccords au moyen de ruban isolant.
5. Installer le module dans une boîte de dérivation en faisant en sorte que les cadrans de code soient orientés vers l'extérieur.
6. Rétablir le courant au fusible ou au disjoncteur; L'INSTALLATION EST TERMINÉE.
VÉRIFICATION
Une fois le 6376 raccordé et alimenté conformément aux directives, utiliser le contrôleur de table (nº de cat. 6320) ou un autre contrôleur de la gamme des
CDD pour vérifier le fonctionnement du gradateur modulaire en procédant aux étapes suivantes :
1. Transmettre une commande SOUS TENSION au module; la charge commandée devrait s'allumer.
2. Transmettre une commande HORS TENSION au module; la charge commandée devrait s'éteindre.
3. Transmettre une commande TOUTES LUMIÈRES ALLUMÉES au module; la charge commandée devrait s'allumer.
4. Transmettre une commande TOUT HORS TENSION au module; la charge commandée devrait s'éteindre.
5. Transmettre une commande SOUS TENSION, suivie d'une commande TAMISER au module; la charge commandée devrait s'allumer et se tamiser jusqu'au
niveau programmé. Ensuite, transmettre une commande TOUTES LUMIÈRES ALLUMÉES au module afin de revenir à la pleine intensité. Transmettre une
commande HORS TENSION, suivie d'une commande TOUTES LUMIÈRES ALLUMÉES au module; la charge commandée devrait s'allumer à sa pleine
intensité.
6. Si le 6376 répond de façon appropriée aux commandes décrites ci-dessus, il est prêt à être utilisé.
8/21/01, 1:44 PM
os
de cat. 6385 et 6386) et, le cas échéant, d'installer le matériel de
MD
(CDD) et dans le