Descargar Imprimir esta página

Initial Operation / Basic Setting - LiftMaster CB202EV Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62

INITIAL OPERATION / BASIC SETTING

Proceed step by step. When in doubt, start again at the beginning. Take suffi cient time to make these settings.
1. Are all components required for operation connected? Motor, photocells, safety safety edge, stop switch.
2. Limit switches are fi xed to the rack?
3. Setting of DIPs => all off (settings can be done later)
4. Make sure nobody is present in the gate area.
Note:
When connecting the control board for the fi rst time (no basic setting has been done) the Diagnosis-LED will indicate
the status of the photocell terminals and, depending on the confi guration, blink between 4 and 7 times. This indication
is regular and can be ignored until Basic Setting (also see page 12 "Diagnosis-LED").
Now connect control board to power
BASIC SETTING:
1. Move the gate manually to a position between the two
limit switches OPEN - CLOSE and engage gate opener.
2. Press buttons P1, P2 and P3 at the same time for about
2-3 sec. LED „LEARN" starts to fl ash.
3. Now watch the gate. The gate can be moved in both
directions using the button P1. Press the button P1 several
times (1-2 seconds each time) to understand the function
of the button. If none of the buttons are pressed for about
15 seconds, the control switches back to normal operation.
Repeat step 2 in this section.
4. Fully open the gate with the button P1.
Keep P1 pressed until the controller turns off by itself at
the limit switch OPEN. (Do not release before).
Control: The LED „OPEN LIM" (yellow) = limit switch
OPEN goes on. Otherwise, change the limit switch
position before further settings are made.
5. Close the gate with the button P1 till it is turned off at the
limit switch CLOSED. (Do not release beforehand).
Control: The LED „CLOSE LIM" (yellow) = limit switch
CLOSED goes on.
Basic setting is completed. LED „LEARN" will go out.
The full travel distance and force setting can now be pro-
grammed as described on page 11.
2.
2.
2.
10/14 en

Publicidad

loading