Status Leds - Interlogix TruPortal TP-ADD-2D Serie Referencia Rápida

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1 (NC)
2 (C)
3 (NO)
3
Callout
Description
1
AC transformer
2
AC strike
Reader Wiring
10
11
12
0 1
2 3
13
4 5
6 7
14
8 9
*
#
15
TruPortal Dual Door Interface Quick Reference
1
2
Callout
Description
3
Clamp voltage
>1.5x VAC RMS.
For 24 VAC strike,
Panasonic
ERZ-CO7DK470 is
typical.
1
TB11
1
2
3
4
5
6
1
RED/
5/12 GRN
RXD
R1D1 R1D0
GND
R2D1 R2D0
2
4
6
8
3
5
7
Callout
Description
1
Reader
2
(+) 5/12 VDC
3
Green LED
4
Red LED
5
R1 Data 1
6
R1 Data 0
7
(-) 0V Signal
Ground
8
R2 Data 1
For the second reader of each door, the reader connections are shared
(except for the Data 0 and Data 1 which are separate for each reader).
Jumpers
Reader power for Door 1 [J1] and Door 2 [J2]:
5V = 12V reduced to 5V at door
12V = 12V passed through to reader

Status LEDs

LED 1: This is the Processor OK LED. Its normal action is a slow
2
flash.
LED 2: This is the SNAPP OK LED. If the module serial number is
configured and communicating with the main panel then the LED is
9
on. If the module serial number is not programmed or not
communicating the LED is off.
LED 3: This is the Power BAD LED. If there is insufficient voltage or
current then this LED will flash. If the voltage is normal then the LED
is off.
Magnetic Locks and other "Fail-Safe" Door Locks
The default door lock wiring is for "Fail Secure" (powered = unlocked). For
magnetic-locks and other "Fail-Safe" door locks (powered = locked), move
the NO wire to NC terminal for the specific unlock relay.
Note:
The system shall not be installed in the fail secure mode unless
permitted by the local authority having jurisdiction and shall not
interfere with the operation of panic hardware. (Not evaluated by
UL.)
2
Callout
Description
9
R2 Data 0
10
Red (1)
11
Brown (4)
12
Orange (5)
13
White (3)
14
Green (2)
15
Black (6)
1
NC
2
Com
X
3
NO
P/N 460802991B 26JAN12 en-US

Publicidad

Tabla de contenido
loading

Tabla de contenido